User guide

7510r Programming Reference - Reporting
Page 57
Close (see note 1)
Zone Omitted (Channel 5. see note 2)
Burg Partition 1
Burg Partition 2
Burg Partition 3
Burg Partition 4
Alarm Confirmation (required for DD243)
Alarm Abort
Notes:1. Open and Close provide the same functions as
Open/Close, but on two separate channels.
2. Zone Omitted - the control unit sends this signal
when a user omits a zone. (Required for DD243.)
3. The control unit delays reporting/logging either
mains loss, or exiting Installer Menu with mains loss,
by 15-18 min (chosen randomly). For Scandinavia
the control unit waits at least 60 minutes before
reporting.
FF Report Restorals
If you selected Fast Format in the Report Type menu then
you can enable or disable restoral reporting by selecting
Reporting, Alarms, FF Report Restorals. The options
available are:
Disabled
Restore off. The control unit does not communicate
restorals.
Enabled.
Restore on. The control unit does communicate
restorals.
SIA Report Mode
To change the SIA report mode select
Reporting
,
Alarms
,
SIA Report Mode
.
SIA reports are called ‘Telegrams’. Each telegram
contains the site identification number (normally six digits
long) and relevant event information. The amount of
information reported depends on the SIA mode you
select: Basic, Summary, Intermediate, or Full. Table 1 on
the next page shows the types of report for each mode.
(Note that each mode also contains all the reports in the