Option 2-5-3-1 – Connect
Establish a connection with the PC running Downloader, but take no further action. (The
specific account for the control unit must be open on Downloader before you start the
call.)
Option 2-5-3-2 – Upload from PC*
Once connected, Downloader sends configuration data to the control unit, and then drops
the connection.
Option 2-5-3-3 – Download to PC*
Once connected, the control unit sends configuration data to Downloader, and then drops
the connection.
Option 2-5-3-4 – Diagnostic*
Once connected, Downloader performs a simple remote service check and then drops the
connection. Downloader ignores any log event data or configuration data. The control unit
does NOT change the next remote service date and time.
Option 2-5-3-5 – Remote Service*
Once connected, Downloader performs the full remote service call and then drops the
connection.
*Note: For options 2 to 5, Downloader must have all accounts closed before you start the call.
Option 2-5-4: Setting Up the RS232 Port
Option 2-5-4-1: Setting the Baud Rate
e.g.
Communication 4
RS232 Options
RS232 Options 1
RS232 Baud
RS232 Baud 7
38400
RS232 Baud 1
600
[
|
[
1. SELECT BAUD RATE
To select the baud rate:
Pr e ss o r
to scroll, or
En t e r h o t ke y (1 -7 )
[
This option allows you to set the baud rate for the serial (RS232) port.
)
This option is available for M2000 panel only.
)
Use a baud rate of 38400 when using the Downloader software.
)
Use a baud rate of 9600 when using an IRIS IP dialer for Downloader.