User`s guide

Engineer Menu 1-1 Engineering Manual
22
1 – Normal Alm
The Normal Alm zone generates an alarm (see below) when the system is set. By default, a
full alarm is generated, unless overridden by option 1-8-4 (page 83).
2 – 24 Hour
This zone is monitored at all times. When triggered in the unset condition, an internal
alarm is generated. When triggered in the set condition, a full alarm is generated, unless
overridden by option 1-8-4 (page 83).
Full, Local and Internal Alarms
A full alarm causes keypad sounders, the extension loudspeaker, external sounders, strobe
and communications to operate.
A local alarm causes keypad sounders, the extension loudspeaker, external sounders and
strobe to operate.
An internal alarm causes only keypad sounders and the extension loudspeaker to operate.
Note: Only keypads and extension loudspeakers assigned to the ward that is in alarm will
sound. The extension loudspeaker is assigned to wards using the Panel Speaker attribute
(page 36). Keypads are assigned to wards using option 1-3-1 (page 34).
The external sounder and strobe can be disabled using the Bell & Strobe ward attribute (p 37).
The alarm response can be overridden when a ward group is set by using option 1-8-4 (p 83).