User`s guide

Engineer Menu 1-9 Engineering Manual
84
Option 1-9: Choosing the Configuration Options
Configuration 2
DD243
DD243 1
Confirmation On
[
1234567890123456
1234567890123456
Eng 1 Menu 9
Configuration
DD243 2
Sndrs on Unconf
Configuration 1
General
[
|
|
e.g.
e.g.
To selec t the c onfig uration type:
Pr e ss o r
to sc roll, or
Press the option hot key
To selec t the c onfig uration option:
Pre ss o r to sc ro ll, o r
Press the option hot key
Pr e s s
r
to toggle setting
1 . SELEC T W HETHER TO C O N FI G URE
GENERAL, DD243 OR EN50131
2. SELECT CONFIGURATION OPTION
Option 1-9-1: Choosing General Configuration Options
(For defaults see page 133.)
01 – Ward OFF / Ward ON
Ward OFF With this option selected, a zone that is in multiple wards is armed when any
one of its wards is set. The zone is disarmed when any one of its wards is unset.
Ward ON – With this option selected, a zone that is in multiple wards is armed only if all of
its wards are set. The zone is disarmed when any one of its wards is unset.
02 – Bell Is an SAB / Bell is an SCB
Bell Is an SAB – The control panel bell output applies 0V when active.
Bell is an SCB – The control panel bell output removes 0V when active.
03 – View Alms Unset / View Alms P.set
View Alms Unset – When the system is part set and an alarm occurs in a set ward, no
information is displayed until the system is unset. The user can display details of the alarm
by entering a user code and viewing the Alerts.
View Alms P.set– When the system is part set and alarm occurs in a set ward, the alarm
information is displayed on all keypads immediately the alarm occurs.
04 – Engr Authorised / User Authorised
Engr Authorised – When using Downloader software, data in the control panel can be
overwritten without the user's knowledge.
User Authorised – When using Downloader software, data in the control panel can be
overwritten only with user authorisation, from User option 2-6-1 (see the
Manager's
Manual
).