Operator`s manual

‘Phones 2 & 3’
‘PL’ assigns private line to these outputs.
Main to AB/CD
Assigns either A, B or C, D to the phones outputs.
Main/AUX
Assigns either main A, B, C, D or Aux. 1, 2 to the outputs.
(Note: Left out = A, C, A1; Right out = B, D, A2.)
Phones Select
Further sub-selects signal to the outputs.
(eg: Phones 2 could be A only.) (Main to AB to L.)
X Phones 2, 3 follow the phones 1 selection. For example, tape return (playback) can be directed to these
outputs. (Phones 2 & 3 are completely independent from each other.)
Run 1A - This is the unmarked position to the left of ‘L’ on the phones 2, 3 select switch.
Meter Bridge Switches
Power;
Internal /
External: Switch to internal when using batteries. It is recommended to use alkaline D cells. Rechargeable (Nicad
cells) may also be used with reduced battery life. Pin 3 of power XLR is the positive charger input.
Pin 1 - negative.
Light: Supplies 12v DC to the BNC connector. A Littlite may be mounted to this connector. Be aware
that a battery operated light bulb consumes considerable current.
Mix. Bus
These are inputs only. Another mixer output may be inserted at this point to increase the number of
input channels. Note: A resistor (eg: 10 k) needs to be installed in line with each input. An interface box
is available (CSMB) with a ‘D’ connector and four 1/4” jacks with in line resistors.
Power Supply Suggestions
An external AC to DC power supply may be connected to Pin 1 (-), Pin 4 (+) of the XLR-4.
The requirements are that output voltage is regulated and filtered, with a DC voltage level of 12 to 24
volts and a current rating of > 1 Amp. A 30 watt linear power supply is very suitable. We recommend
using a linear type supply (rather than a switching type) as, in general, the output ripple and noise of the
supply is less. Some switching supplies can output high frequency noise that can interfere with the
internal DC-DC converter & microphones that have internal converters.
Side Panels
1/4” - 28 holes are provided to mount the mixer to a cart.
Screws can be up to 1” long (25.4 mm).
MODEL CS 208
25
OPERATION & APPLICATION NOTES
Left Page
Left Page