Operating & Service Manual 90093-IM 05/11/2011 Airetool ® CC-325-HP High Pressure Water Flush Condenser Tube Cleaner For additional product information visit our website at http://www.apextoolgroup.
Safety Recommendations For your safety and the safety of others, read and understand the safety recommendations and operating instructions before operating an Airetrol. When using right angle Airetrols, be sure the throttle is positioned relative to the angle head so that the throttle will not become wedged against an adjacent object in the “ON” position due to torque reaction. The angle head may be repositioned with respect to the lever to accomodate proper location for the task.
Safety Recommendations ADDITIONAL SAFETY RECOMMENDATIONS FOR USE OF RIGHT ANGLE AIRETROLS * Tasks should be performed in such manner that the wrists are maintained in a neutral position, which is not flexed, hyperextended, or turned side to side. * Stressful postures should be avoided and can be controlled through tool selection and work location.
Operating & Service Instructions CC-325-HP High Pressure Water Flush Condenser Cleaner Motor SPECIFICATIONS FLUSHING AGENT Recommended Air Pressure - 90/100 psi. Air Volume Required - 200 cfm. Minimum Hose Size - 1” I. D. Air Line Lubricator - 15/20 Drops Per Minute (10W Oil) Maximum Flushing Pressure - 5000 psi (water/scavenging Agent) Approximate Peak Power - 6 hp.
Operating & Service Instructions - continued -continuedpoint. With the proper size Allen wrench, reach down through the thrust nut No. 14, in one of the elongated slots and loosen the two set screws that are in the thrust nut. Rotate the shaft until the set screws appear. After loosening the set screws, use a wrench and rotate the spindle in a counterclockwise rotation which will unthread the thrust nut from the shaft.
Operating & Service Instructions -continuedtate the shaft 180 degrees and tighten the other set screw. This adjustment should be adequate to allow the bearing to absorb the hydraulic thrust from the high pressure but should not induce preloading on the bearing during assembly. With the seal support installed, the shaft should rotate freely without binding. bly. Gears, bearings and grease retainers should be packed with grease.
Parts List For Model CC-325-HP Condenser Cleaner Motor With High Pressure Water Flush ITEM # 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 PART # DESCRIPTION 8010619 1715657 1715320 1235700 1234500 8010024 1228900 8010075 1228800 1228100 8010001 1228700 1238300 1715340 3229500 3229400 8000800 1715360 3167600 1715390 1715330 1715370 1715350 1236200 1147500 1030700 1236300 1237600 1237200 1237500 1237400 1236900 1238200 1235500 8010023 QUANTITY CD-11 Cap 1
Parts List For Model CC-325-HP Condenser Cleaner Motor With High Pressure Water Flush ITEM # 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 NS NS NS NS NS NS NS NS NS PART # DESCRIPTION 1236100 1237900 1234700 1234600 1236400 1235100 1234800 1234900 1181100 1234400 1238000 1238100 1237000 1237300 8005600 3241600 1228600 1236600 1715661 2996558 2996559 1716357 8010318 8566880 QUANTITY CC-37501-B-1 Front Cap CC-37533 Front Cap Gasket CC-32532 Case Cover Gasket CC-32510 Drive Gear CC-37508 Bearing CC-35007-F
Parts Drawing For Model CC-325-HP Condenser Cleaner Motor With High Pressure Water Flush 9
DRIVE TUBE I.D. Inch. (mm) SHAFT DIAMETER Inch. (mm) DRIVE SHAFT .291"-.358" 7.39-9.09 mm 1/4" 6.35 mm CC-336 .359"-.420" 9.09-10.67mm 5/16" 7.94 mm CC-332 .421"-.483" 10.67-12.27 mm 3/8" 9.52 mm CC-324 .484"-.608" 12.27-15.44 mm 7/16" 11.11 mm CC-316 .609"-.737" 15.44-18.72 mm 1/2" 12.7 mm CC-312 .738"-.831" 18.72-21.11 mm 9/16" 14.29 mm CC-308 .832"-1.055" 21.11-26.80 mm 5/8" 15.88 mm CC-304 1.056"-1.561 26.80-39.65 mm 3/4" 19.05 mm CC-320 1/650"-2.374" 39.65-60.30 mm 1" 25.
TUBE I. .D inch mm .291-.306 .307-.321 .322-.337 .338-.353 .359-.389 .390-.420 .421-.452 .453-.483 .484-.514 .515-.545 .546-.577 .578-.608 .578-.608 .609-.639 .640-.675 .676-.706 .707-.737 .738-.769 .770-.800 .801-.831 .832-.862 .863-.894 .895-.925 .926-.956 .957-.987 .988-1.024 1.025-1.055 1.056-1.086 1.087-1.117 1.118-1.149 1.150-1.180 1.181-1.211 1.212-1.242 1.243-1.280 1.281-1.311 7.39-7.77 7.77-8.15 8.18-8.56 8.59-8.97 9.12-9.88 9.91-10.67 10.69-11.48 11.48-12.27 12.29-13.06 13.08-13.84 13.87-14.
Selection Guide - continued TUBE I. D. inch mm .291-.306 .307-.321 .322-.337 .338-.353 .359-.389 .390-.420 .421-.452 .453-.483 .484-.514 .515-.545 .546-.577 .578-.608 .578-.608 .609-.639 .640-.675 .676-.706 .707-.737 .738-.769 .770-.800 .801-.831 .832-.862 .863-.894 .895-.925 .926-.956 .957-.987 .988-1.024 1.025-1.055 1.056-1.086 1.087-1.117 1.118-1.149 1.150-1.180 1.181-1.211 1.212-1.242 1.243-1.280 1.281-1.311 7.39-7.77 7.77-8.15 8.18-8.56 8.59-8.97 9.12-9.88 9.91-10.67 10.69-11.48 11.48-12.27 12.
Sales & Service Centers Note: All locations may not service all products. Please contact the nearest Sales & Service Center for the appropriate facility to handle your service requirements.