Healthcare solutions Arrow Hart The critical demand for consistent, reliable connectivity in a healthcare environment requires quality device solutions
Reliable, code-compliant healthcare devices deliver solutions for the medical services environment Table of Contents Hospital Grade Testing 3 Healthcare Product Solutions CuVerro® devices Product Information CuVerro® switches & wallplates 11-12 4 USB charging devices Critical care 5 Straight blade receptacles Nurses' stations 5 ArrowLink modular connectors 16 Pediatric care 6 SPD receptacles 18 Patient & examining rooms 6 Ground fault circuit interrupters 19 Radiographic rooms 7 Pow
NEC® & UL listed hospital grade device requirements The National Electric Code® Article 517 identifies device features for designated health care environments where medical, dental, psychiatric, nursing, obstetrical, or surgical care are provided. Certain applications have special device requirements to ensure the protection of the patients, providers and equipment.
CuVerro® antimicrobial copper surfaces What is CuVerro®? CuVerro® is a new type of touch surface material designed specifically for areas where cleanliness is a concern. • When cleaned regularly, kills more than 99.9% of bacteria* within 2 hours and continues to kill 99% of bacteria* even after repeated contamination • Registered by the U.S.
Critical care and nurse's stations Critical care Challenge Electrical Integrity Reliable power quality is required by sensitive equipment, under repetitive abuse Electrical Integrity Dependable ground continuity of wiring devices protects both personnel and patients from compromised electrical connections Environmental Durability Corrosion resistance is a necessary feature where frequent washdowns result in excess moisture that can compromise performance Ease of Installation Replacement of wiring devices m
Pediatric care, patient rooms & examining rooms Pediatric care Challenge Solutions Safety Keeping children safe Receptacles • Shock Sentry lockout protects against mis-wiring and GFCI circuitry damage; large indicator light shows tripped or end-of-life condition Aesthetics Removing the clinical and impersonal feel of healthcare environments • UL Listed safety shutter system prevents insertion of foreign objects • NEC Article 517.
Radiographic rooms, hallways & corridors Radiographic rooms Challenge Electrical Integrity The quality of the power is a vital factor in preventing possible electrical damage to highly sensitive and expensive radiographic equipment Environmental Durability Device durability directly equates to device longevity, a necessary factor in reducing equipment down-time Ease of Installation The safety of personnel, patients and the entire radiographic environment can often depend on secure device connections Solut
Lobbies, waiting rooms, conference rooms & offices Lobbies & waiting rooms Challenge Solutions Safety The use of tamper resistant receptacles protects children from electrical shock resulting from the insertion of foreign items Aesthetics Our decorator devices and screwless wallplates replace clinical-looking devices and wallplates Decorator devices • Tamper resistant specification grade receptacles help keep children safe • CuVerro® toggle insert constructed of EPA registered CuVerro® antimicrobial
Public restrooms, patient bathrooms, kitchens & food service Public restrooms & patient bathrooms Challenge Solutions Safety Safety is a priority in areas where there is potential for electricity and water to interact GFCI receptacles Energy Efficient Areas with infrequent occupancy represent excellent opportunities for lighting control via occupancy sensors • Shock Sentry lockout protects against mis-wiring and GFCI circuitry damage • Integral tamper resistant shutters for child safety • When dow
Maintenance, physical plants & outdoor facility areas Maintenance & physical plant areas Challenge Solutions Electrical Integrity Power reliability is an absolute necessity for devices that enable basic facility comfort and critical services without interruption Environmental Durability Abusive environments with heavy loads, vibration, dust and dirt, potential impact, extreme temperatures require special devices Environmental Durability Exposure to moisture and contaminants can stop many electrical device
CuVerro® specification grade AC switches Product Description Single-pole, double-pole, 3-way, 4-way 15A & 20A, 120/277V/AC Design features for CuVerro® switches • Touch surfaces constructed of EPA registered** CuVerro® antimicrobial copper • When cleaned regularly, CuVerro® antimicrobial copper surface delivers continuous and ongoing antibacterial* action, remaining effective in killing greater than 99.
CuVerro® specification grade wallplates Product Description Standard size Toggle, single & duplex receptacle, decorator, blank box-mounted Design features for CuVerro® wallplates 93401CUR • Touch surfaces constructed of EPA registered** CuVerro® antimicrobial copper • When cleaned regularly, CuVerro® antimicrobial copper surface delivers continuous and ongoing antibacterial* action, remaining effective in killing greater than 99.
USB charging devices Product Description 2-pole, 3-wire grounding 15A 125V, 5V/DC, 2.1A, 20A 125V, 5V/DC, 2.1A Design features for hospital grade combination USB receptacle • Hospital grade AC duplex receptacle with two USB charging ports rated at 2.
Premium hospital grade straight blade receptacles Product Description G G W 2-pole, 3-wire grounding 15A 125V, 15A 250V, 20A 125V, 20A 250V 5-15R G G W 5-20R 6-15R 6-20R Design features for premium hospital grade receptacles AH8200 8310 • Exclusive screw terminal guards provide fast, easy insulation from conductive surfaces (Cat No. AH8200/AH8300) • 0.050" (1.
Hospital grade straight blade receptacles Product Description G G W 2-pole, 3-wire grounding 15A 125V, 20A 125V W 5-20R 5-15R Design features for hospital grade duplex receptacles • Tamper resistant shutters provide compliance with 2011 NEC® Article 517.18(C) that states that receptacles located in pediatric areas of a hospital must be tamper resistant • 0.037" (0.
Hospital grade straight blade isolated ground receptacles Product Description G G W 2-pole, 3-wire isolated ground 15A 125V, 20A 125V, 20A 250V 5-15R G W 6-20R 5-20R Design features for isolated ground hospital grade receptacles • Exclusive screw terminal guards provide an insulating barrier • Exclusive 5-leaf, brass line contacts ensure lowest heat rise, smooth plug blade insertion and long-term retention • Rigid, glass reinforced nylon base lends ultimate strength and superior high heat resi
Hospital grade decorator straight blade receptacles Product Description G G W 2-pole, 3-wire grounding 15A 125V, 20A 125V, 20A 250V W 5-20R 5-15R Design features for decorator hospital grade duplex receptacles • Exclusive 5-leaf brass line contacts ensure lowest heat rise, smooth plug blade insertion, long-term retention and corrosion resistance • Rigid, glass reinforced nylon base lends ultimate strength and superior high heat resistance in contact carrier • 0.050" (1.
Hospital grade SPD receptacles Product Description G G W 2-pole, 3-wire grounding 15A 125V, 20A 125V 5-15R W 5-20R Design features for SPD receptacles with LED indicators and switched alarms 8200__S • Provides surge protection for hot to neutral and hot to ground • 8-hole back and side wired • Shallow depth for easy installation • Green LED indicators to verify surge protection and ground • Audible alarm indicates compromised connection or surge protection has expired • Front access swit
Hospital grade GFCIs Product Description G G W 2-pole, 3-wire grounding 20A feed-through rating 15A 125V, 20A 125V W 5-20R 5-15R Design features for hospital grade duplex GFCI receptacles • UL Listed, fully compliant with all latest UL943 (4th edition) Class A GFCI, UL498 hospital grade requirements • Shock Sentry lock-out function protects from miswired line-load connections and GFCI circuitry damage • Large visual indicator light provides quick visual reference of a tripped or “end of life” co
Hospital grade receptacles Product Description W G 2-pole, 3-wire grounding 20A 125V W GR B 5-20R Design features for "hospital only" power-lock single receptacles • Fits all standard single receptacle wallplates • Binding screw type, for side wiring Receptacle 2-Pole, 3-Wire Hospital Use Back & Side Wire - Short Strap Catalog No. 23050 Description Amp Volt NEMA Color Power-lock hospital use single receptacle 20 125 5-20R BK • NNote: Catalog No.
Hospital use mobile X-ray power-lock devices Product Description GR 2-pole, 3-wire grounding 50A 250V, 60A 250V Plug 50A 250V GR GR Receptacle 50A 250V Plug 60A 250V GR Receptacle 60A 250V Design features for hospital use power-lock receptacles • Fiberglass reinforced nylon interior • 12" (304.8mm), #6 AWG wire leads Receptacles - Stainless Steel Plate Assembly Catalog No.
Hospital grade plugs and connectors Product Description G G W 2-pole, 3-wire grounding 15A 125V, 15A 250V, 20A 125V, 20A 250V 5-15R G G G G W 5-20R 6-15R 6-15R 6-20R 6-20R Design features for hospital grade plugs & connectors AH8215HG • Marked “hospital grade” and identified with “green dot” symbol • Ultra grip series ergonomically designed for comfort and stability • EPDM rubber gasket in ultra grip series and neoprene gasket in safety grip seals cord hole on straight plugs and connectors
Hospital grade plugs and connectors Product Description G G W 2-pole, 3-wire grounding 15A 125V, 20A 125V W 5-20R 5-15R Design features for quick grip hospital grade plugs & connectors • Single-piece hinged body reduces number of assembly screws to speed installation • Unique terminal configuration places screws in only two directions, reducing installation time • Clear terminal cover and large, funneled wire entry ensures quick and accurate wiring • Signature exterior design molds to hand wit
Hospital grade plugs and connectors Product Description G G W 2-pole, 3-wire grounding 15A 125V, 15A 250V, 20A 125V, 20A 250V G G G G W 5-20R 5-15R 6-15R 6-15R 6-20R 6-20R Design features for polycarbonate hospital grade plugs & connectors 8266 • High impact-resistant polycarbonate housings • Assembly screws are speed-threaded and captive, reducing installation time • Solid brass plug blades are firmly embedded in body • See-through terminal cover and body allows inspection of connection
Pre-marked special use wallplates Product Description Standard size Mid-size Design features for specification grade thermoplastic wallplates EMERGENCY • Virtually unbreakable plates reduce installation and replacement costs • Preferred for industrial, institutional and other high traffic areas • Exclusive timesaving Screw-Catch feature holds mounting screws captive and simplifies installation • High gloss finish is soil-resistant GFCI PROTECTION Hospital Grade Pre-Marked Special Use Wallplates C
Commercial specification grade LED lights Product Description 120/277V, 60Hz Design features for commercial specification grade LED accent lights LNL3 series • Fits into a standard junction box for easy installation (single-gang, handy box, 2" minimum inside width) • Delivers minimum 30 lumens of illumination • Energy-efficient LED light source • Illumination colors include white (4000K), amber, red, and blue • Ship with 4 color lenses that are quickly and easily field-installable • Lenses are
A sampling of hospital grade tests Eaton's Arrow Hart hospital grade wiring devices meet or exceed all the UL498 hospital grade standards Hospital Grade Grounding Contact Overstress Plugs & Connectors Receptacles Testing Crushing Test For plugs and connectors, a gradually escalated and removed crushing force between two steel plates of 500 lbf is applied to the bodies of the wired devices. Devices must not break, deform or otherwise become incapable of function Conditioning: Oversized .
*Laboratory testing shows that, when cleaned regularly, CuVerro® antimicrobial copper surfaces kill greater than 99.9% of the following bacteria within 2 hours of exposure: MRSA, Staphylococcus aureus, Enterobacter aerogenes, Pseudomonas aeruginosa, Vancomycinresistant Enterococcus faecalis (VRE), and E. coli O157:H7.