Product Brochure
Compliances, specifications and availability are subject to change without notice.
20
EATON Arrow Hart Industrial grade straight blade & locking devices
15 & 20A Hospital Grade
Plugs & Connectors
15 & 20A Hospital Grade
Quick Grip Plugs & Connectors
15 & 20A
Plugs & Connectors
15 & 20A Quick Grip
Plugs & Connectors
NEMA Config 5-15, 6-15, 5-20, 6-20 5-15 5-15, 6-15, 5-20, 6-20 5-15, 6-15, 5-20, 6-20
Wiring Type Back wire Back wire Back wire Back wire
Environmental
Specifications
Flammability:
Meets UL94 requirements; V2 rated
Temperature Rating:
-40°C to 75°C (-40°F to 167°F)
Flammability:
Meets UL94 requirements; V2 rated
Temperature Rating:
-40°C to 75°C (-40°F to 167°F)
Flammability:
Meets UL94 requirements; V2 rated
Temperature Rating:
-40°C to 75°C (-40°F to 167°F)
Flammability:
Meets UL94 requirements; V2 rated
Temperature Rating:
-40°C to 75°C (-40°F to 167°F)
Electrical
Specifications
Dielectric Voltage:
Twice the device rating + 1000V
per UL498
Current Interrupting:
Yes, at full-rated current
Temperature Rise:
Max. 30ºC (86°F) after 250 cycles of
overload @ 200% of rated current (DC)
Dielectric Voltage:
Twice the device rating + 1000V
per UL498
Current Interrupting:
Yes, at full-rated current
Temperature Rise:
Max. 30ºC (86°F) after 50 cycles of
overload @ 150% of rated current (DC)
Dielectric Voltage:
Twice the device rating + 1000V
per UL498
Current Interrupting:
Yes, at full-rated current
Temperature Rise:
Max. 30ºC (86°F) after 250 cycles of
overload @ 200% of rated current (DC)
Dielectric Voltage:
Twice the device rating + 1000V
per UL498
Current Interrupting:
Yes, at full-rated current
Temperature Rise:
Max. 30ºC (86ºF) after 250 cycles of
overload @ 200% of rated current (DC)
Mechanical
Specifications
Terminal Accommodation:
#18 - #12 AWG
Voltage Ratings:
Permanently marked on device
Terminal Accommodation:
#18 - #12 AWG
Voltage Ratings:
Permanently marked on device
Terminal Accommodation:
#16 - #12 AWG
Voltage Ratings:
Permanently marked on device
Terminal Accommodation:
#18 - #12 AWG
Voltage Ratings:
Permanently marked on device
15 & 20A Hospital Grade
Plugs & Connectors
15 & 20A Hospital Grade
Quick Grip Plugs & Connectors
15 & 20A
Plugs & Connectors
15& 20A Quick Grip
Plugs & Connectors
NEMA Config 5-15, 6-15, 5-20, 6-20 5-15 5-15, 6-15, 5-20, 6-20 5-15, 6-15, 5-20, 6-20
Outer Shell Nylon Nylon Nylon Nylon
Interior Body Nylon N/A Nylon N/A
Terminal Retainer Polycarbonate Polycarbonate Polycarbonate Polycarbonate
Blades 0.060" thick brass 0.060" thick brass 0.062" thick brass 0.060" thick brass
Line Contacts 0.031" thick brass 0.031" thick brass 0.031" thick brass 0.031" thick brass
Terminal Clamps Steel, zinc plated Steel, zinc plated Steel, zinc plated Steel, zinc plated
Terminal Screws
#8-32 steel, brass plated (hot)
and zinc plated (neutral screw)
#8-32 steel, brass plated (hot)
and nickel plated (neutral screw)
#8-32 steel, brass plated (hot)
and nickel plated (neutral screw)
#8-32 steel, brass plated (hot)
and nickel plated (neutral screw)
Ground Contact Brass Brass 0.041" thick brass Brass
Ground Screw #8-32 steel, zinc plated (green) #8-32 steel, zinc plated (green) #8-32 steel, zinc plated (green) #8-32 steel, zinc plated (green)
Assembly/
Mounting Screws
Steel, nickel plated Steel, zinc plated Steel, nickel plated Steel, zinc plated
Cord Clamp Nylon Nylon Nylon Nylon
Cord Clamp
Screws
Steel Steel Steel Steel
Gasket/Dust Shield EPDM N/A EPDM N/A
Table 11. Specifications for Plugs & Connectors
Table 12. Materials for Plugs & Connectors
Arrow Hart industrial grade straight blade specifications