Energy Guide
www.cooperwiringdevices.com
Modular Receptacles
Project Name: Prepared By:
Project Number: Date:
Catalog Number: Type:
MATERIAL CHARACTERISTICS
• Nylon with PVC terminal guards, except single: adhesive terminal barrier
• Environmental, Base Device: Flammability meets UL 94 requirements; V2 rated; temperature
rating: -20ºC to 90ºC (-4ºF to 194ºF), except single: -20ºC to 60ºC (-4ºF to 140ºF)
• Environmental, ArrowLink: Flammability meets UL 94 requirements; V2 rated; temperature
rating: -20ºC to 90ºC (-4ºF to 194ºF) max.
TESTING & CODE COMPLIANCE
• Base Device: cULus Listed to UL 498 and UL 943, file no.
E60120; meets all UL 943 (GFCI) and UL 498 (Receptacles)
and applicable CSA requirements
• ArrowLink: Plug & connector cULus Listed to UL 2459 file no.
E325188
• Combined: cULus Listed wiring assembly, UL file no. E326691
1.30"
(33.0mm)
4.19"
(106.4mm)
3.28"
(83.3mm)
Depth with
ArrowLink
1.65"
(41.9mm)
TRVGF15_MOD
2-Pole, 3-Wire Grounding
15A 125V/AC
20A 125V/AC
Ground Fault Circuit
Interrupter Receptacles
Specification Grade GFCIs
Catalog No. Catalog No.
Description Color Suffix Color Suffix
Duplex GFCI
■■
VGF15___MOD
•
■■
VGF20___MOD
•
A, B, BK, GY, LA, RD, V, W A, B, BK, GY, LA, RD, V, W
Duplex GFCI
■■
VGF15F___MOD
••
■■
VGF20F___MOD
••
NAFTA Compliant B, BK, GY, LA, RD, V, W B, BK, GY, LA, RD, V, W
Tamper Resistant
■■
TRVGF15___MOD
•
■■
TRVGF20___MOD
•
Duplex GFCI A, B, BK, GY, LA, RD, V, W A, B, BK, GY, LA, RD, V, W
Tamper Resistant
■■
TRVGF15F___MOD
••
■■
TRVGF20F___MOD
••
Duplex GFCI B, BK, GY, LA, RD, V, W B, BK, GY, LA, RD, V, W
NAFTA Compliant
Weather Resistant
■■
WRVGF15___MOD
•
■■
WRVGF20___MOD
•
Duplex GFCI B, GY, V, W B, GY, V, W
Tamper & Weather
■■
TWRVGF15___MOD
•
■■
TWRVGF20___MOD
•
Resistant Duplex GFCI B, GY, LA, V, W B, GY, LA, V, W
Includes standard size unbreakable wallplate unless otherwise noted
Consult factory customer service representative for additional packaging options
Back Wire & 15A, 125V 20A, 125V
Side Wire NEMA 5-15R NEMA 5-20R
426
426
• Pre-wired plugs provide 100% inspected and
consistent torque settings.
• Exclusive screw terminal guards insulate
conductive surfaces.
• Tamper Resistant models comply with 2008
NEC
®
Article 406.11 for all dwelling units.
• ShockSentry™ lock-out function prevents miswired
line-load connections and GFCI circuitry damage.
FEATURES
• ArrowLink modular plug and connector incorporate
a first make/last break grounding design.
• Wire leads (where applicable) are crimped and
resistance welded to plug and connector
terminals.
• Audible “click” when mating plug and connector
indicates proper assembly.
Tamper Resistant
Tamper Resistant
Icon Key
Build-To-Spec Customizable Devices
NAFTA Compliant, see Arrow Hart Buyer’s
Guide pg O-30 for more information
0.40"
(10.2mm)
1.08"
(27.4mm)
1.42"
(36.1mm)
Receptacle Plug
0.57"
(14.5mm)
1.33"
(33.8mm)
1.46"
(37.1mm)
Lead
Length:
6.00”
(152.4mm)
Receptacle SPD Screw
Terminal Connector
0.51"
(13.0mm)
1.15"
(29.2mm)
1.42"
(36.1mm)
Lead
Length:
6.00”
(152.4mm)
Leaded Receptacle
Connector
Type Description Catalog No.
ArrowLink SPD Push-In Building Wire Connector
■■
MCR300FTPI
Push-In Building Wire Connector, No Ground Conductor
■■
MCR300FTPING
ArrowLink SPD Screw Terminal Building Wire Connector
■■
MCR300FTST
Screw Terminal Building Wire Connector, No Ground Conductor
■■
MCR300FTSTNG
ArrowLink 125V Solid Wire Building Wire Connector
■■
MCR125SOL
125V Stranded Wire Building Wire Connector
■■
MCR125STR
250V Solid Wire Building Wire Connector
■■
MCR250SOL
250V Stranded Wire Building Wire Connector
■■
MCR250STR
Patent Pending
ArrowLink Receptacle Connectors
0.58"
(14.7mm)
1.38"
(35.1mm)
1.46"
(37.1mm)
Lead
Length:
6.00”
(152.4mm)
including
ground screw
& ring terminal
Receptacle SPD Push-In
Connector