Energy Guide

www.cooperwiringdevices.com
Modular Receptacles
Project Name: Prepared By:
Project Number: Date:
Catalog Number: Type:
MATERIAL CHARACTERISTICS
Nylon with PVC terminal guards, except single: adhesive terminal barrier
Environmental, Base Device: Flammability meets UL 94 requirements; V2 rated; temperature
rating: -20ºC to 90ºC (-4ºF to 194ºF), except single: -20ºC to 60ºC (-4ºF to 140ºF)
Environmental, ArrowLink: Flammability meets UL 94 requirements; V2 rated; temperature
rating: -20ºC to 90ºC (-4ºF to 194ºF) max.
TESTING & CODE COMPLIANCE
Base Device: cULus Listed to UL 498 and UL 943, file no.
E60120; meets all UL 943 (GFCI) and UL 498 (Receptacles)
and applicable CSA requirements
ArrowLink: Plug & connector cULus Listed to UL 2459 file no.
E325188
Combined: cULus Listed wiring assembly, UL file no. E326691
1.30"
(33.0mm)
4.19"
(106.4mm)
3.28"
(83.3mm)
Depth with
ArrowLink
1.65"
(41.9mm)
TRVGF15_MOD
2-Pole, 3-Wire Grounding
15A 125V/AC
20A 125V/AC
Ground Fault Circuit
Interrupter Receptacles
Specification Grade GFCIs
Catalog No. Catalog No.
Description Color Suffix Color Suffix
Duplex GFCI
VGF15___MOD
VGF20___MOD
A, B, BK, GY, LA, RD, V, W A, B, BK, GY, LA, RD, V, W
Duplex GFCI
VGF15F___MOD
••
VGF20F___MOD
••
NAFTA Compliant B, BK, GY, LA, RD, V, W B, BK, GY, LA, RD, V, W
Tamper Resistant
TRVGF15___MOD
TRVGF20___MOD
Duplex GFCI A, B, BK, GY, LA, RD, V, W A, B, BK, GY, LA, RD, V, W
Tamper Resistant
TRVGF15F___MOD
••
TRVGF20F___MOD
••
Duplex GFCI B, BK, GY, LA, RD, V, W B, BK, GY, LA, RD, V, W
NAFTA Compliant
Weather Resistant
WRVGF15___MOD
WRVGF20___MOD
Duplex GFCI B, GY, V, W B, GY, V, W
Tamper & Weather
TWRVGF15___MOD
TWRVGF20___MOD
Resistant Duplex GFCI B, GY, LA, V, W B, GY, LA, V, W
Includes standard size unbreakable wallplate unless otherwise noted
Consult factory customer service representative for additional packaging options
Back Wire & 15A, 125V 20A, 125V
Side Wire NEMA 5-15R NEMA 5-20R
426
426
Pre-wired plugs provide 100% inspected and
consistent torque settings.
Exclusive screw terminal guards insulate
conductive surfaces.
Tamper Resistant models comply with 2008
NEC
®
Article 406.11 for all dwelling units.
ShockSentry™ lock-out function prevents miswired
line-load connections and GFCI circuitry damage.
FEATURES
ArrowLink modular plug and connector incorporate
a first make/last break grounding design.
Wire leads (where applicable) are crimped and
resistance welded to plug and connector
terminals.
Audible “click” when mating plug and connector
indicates proper assembly.
Tamper Resistant
Tamper Resistant
Icon Key
Build-To-Spec Customizable Devices
NAFTA Compliant, see Arrow Hart Buyer’s
Guide pg O-30 for more information
0.40"
(10.2mm)
1.08"
(27.4mm)
1.42"
(36.1mm)
Receptacle Plug
0.57"
(14.5mm)
1.33"
(33.8mm)
1.46"
(37.1mm)
Lead
Length:
6.00”
(152.4mm)
Receptacle SPD Screw
Terminal Connector
0.51"
(13.0mm)
1.15"
(29.2mm)
1.42"
(36.1mm)
Lead
Length:
6.00”
(152.4mm)
Leaded Receptacle
Connector
Type Description Catalog No.
ArrowLink SPD Push-In Building Wire Connector
MCR300FTPI
Push-In Building Wire Connector, No Ground Conductor
MCR300FTPING
ArrowLink SPD Screw Terminal Building Wire Connector
MCR300FTST
Screw Terminal Building Wire Connector, No Ground Conductor
MCR300FTSTNG
ArrowLink 125V Solid Wire Building Wire Connector
MCR125SOL
125V Stranded Wire Building Wire Connector
MCR125STR
250V Solid Wire Building Wire Connector
MCR250SOL
250V Stranded Wire Building Wire Connector
MCR250STR
Patent Pending
ArrowLink Receptacle Connectors
0.58"
(14.7mm)
1.38"
(35.1mm)
1.46"
(37.1mm)
Lead
Length:
6.00”
(152.4mm)
including
ground screw
& ring terminal
Receptacle SPD Push-In
Connector

Summary of content (2 pages)