Specification

5
. Use only #14 or #12 copper wire rated for at least 75º C with these devices. Do not use with aluminum wire.
6
. For use ONLY with permanently installed fixtures of these types: Incandescent and Magnetic Low Voltage (MLV)
7. To avoid overheating and possible damage to other equipment, do not use to control receptacles.
8
. Use only #14 or #12 copper wire with these devices.
I
nstalling OS106D1 & VS106D1
Refer to the wiring diagram and install the sensor according to these directions.
Y
ou must verify that a neutral wire is available in the wallbox.
1
. The sensor black wire will connect to the hot wire (black) in the wallbox.
2. The sensor red wire will connect to the wire which goes to the light fixture.
3. The sensor white wire will connect to the neutral wire (white) in the wallbox.
4
. The sensor green wire will connect to the ground wire in the wallbox.
5
. Install the sensor loosely using the mounting screws provided.
6. Apply power temporarily and verify that the sensor works by pushing the ON/OFF button to verify the lights turn ON
and OFF. If the lights do not work, then turn off the power and swap the connections on the sensor black and red
w
ires.
7
. Apply power again and verify that the sensor works by pushing the ON/OFF button to verify the lights turn and off.
C
OMPLETING THE INSTALLATION:
1
. Secure sensor into the wall box using two mounting screws provided. Turn the circuit breaker ON.
2. Allow the sensor to stabilize for 10 seconds. The sensor is now ready to detect motion.
3. Verify that Power in ON by pushing the ON/OFF button. Lights and LED should turn ON.
4
. NOTE - The sensor time delay is factory preset (OS106D1 = 5 minutes; VS106D1 = 30 minutes).
5
. If you want to change the time delay proceed as follows:
a. Remove the button from the sensor by pressing in the hooks on the button, and then lift up on the button as
shown in Fig. 1.
b
. Set the time delay using the dial on the right side by using a small Phillips screwdriver. Align the arrow on the
d
ial to desired time delay.
c
. To allow the installer to quickly confirm that the sensor is functioning properly the time delay can be set to
TEST. This will set a time delay of 5 seconds, which allows quick feedback that the sensor is working properly.
6. Replace push button by sliding it upward into the slots in the front housing and push down until the button hook
s
naps into place.
7. Push the ON/OFF button to verify that the lights turn ON/OFF, and that the button operates freely.
8. Install the wallplate.
Daylight Sensing Adjustment (OS106D1 only):
• The Daylight sensing feature prevents lights from turning ON when the room is adequately illuminated by natural light.
NOTE - The factory setting for this adjustment is fully clockwise and permits motion detection to turn ON the lights regardless of
the ambient light level in the room.
• Remove the ON/OFF pushbutton to access the light level adjustment.
• This adjustment must be made when the light level in the room is at the desired level for the lights to turn ON.
• From the clockwise position, turn the dial on the left counterclockwise using a small Phillips screwdriver until the LEDs turns ON
(see Fig. 2).
• Step away from the sensor to allow the device to calibrate to the normal light level in the room. Do not obstruct the natural light.
The calibration process starts when the Night Light turns OFF, and will take approximately 5 seconds. At the end of the calibration
process the sensor will turn the lights ON.
• Replace the ON/OFF pushbutton.
TROUBLESHOOTING:
If you have a problem with your Motion Sensor, first follow this guide. If the problem persists, call the customer service hotline at 1-866-853-4293 between 8:00 A.M. and 6:00 P.M. EST
weekdays.
SYMPTOM POSSIBLE CAUSE SOLUTION
Light does not automatically turn on. 1. Circuit breaker or fuse is turned off. 1. Turn circuit breaker on.
2. Bulb is defective. 2. Replace light bulb.
3. Poor connection. 3. Verify all wiring connections.
4. ON/OFF button not pushed. 4. Press the ON/OFF button.
5. Control may be wired incorrectly. 5. Check wiring.
6. Daylight sensing prevents lights on. 6. Re-adjust daylight sensing level.
7. Manual On mode selected. 7. Set device to Automatic On mode
Light does not automatically turn OFF. 1. Motion is still present. 1. Make sure there is no motion during the time delay period.
2. Time Delay has not expired. 2. No action needed or shorten TIME DELAY.
3. Control may be wired incorrectly. 3. Check wiring.
4. Switch is being triggered by air vent or other heat 4. Determine the source triggering the switch, and alter the air flow.
source.
Light does not stay ON 1. Motion is not detected. 1. Create movement in front of the sensor for 5 seconds..
2. TIME control is set for too short a delay. 2. Set switch TIME control to longer time period.
Remote switch does not work 1. Control may be wired incorrectly. 1. Check wiring
COOPER WIRING DEVICES LIMITED 2 YEAR WARRANTY
Cooper Wiring Devices (CWD) warrants this device to be free of defects in materials and workmanship in normal use and service for a period of two years from date of original
purchase. THIS 2 YEAR LIMITED WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, OBLIGATIONS, OR LIABILITIES, EXPRESSED OR IMPLIED (INCLUDING ANY IMPLIED
WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE THAT IS IN DURATION IN EXCESS OF 2 YEARS FROM THE DATE OF ORIGINAL CONSUMER
PURCHASE). NO AGENT, REPRESENTATIVE, OR EMPLOYEE OF CWD HAS AUTHORITY TO INCREASE OR ALTER THE OBLIGATIONS OF CWD UNDER THIS WARRANTY.
To obtain warranty service for any properly installed CWD device that proves defective in normal use send the defective Occupancy Sensor prepaid and insured to Quality Control
Dept., Cooper Wiring Devices, 203 Cooper Circle, Peachtree City, GA 30269; in Canada: Cooper Wiring Devices, 5925 McLaughlin Road, Mississauga, Ontario L5R 1B8.
CWD will repair or replace the defective unit, at its option. CWD will not be responsible under this warranty if examination shows that the defective condition of the unit was
caused by misuse, abuse, improper installation, alteration, improper maintenance or repair of damage in shipment to CWD.
CWD SHALL HAVE NO RESPONSIBILITY FOR INSTALLATION OF THE SENSOR, OR FOR ANY PERSONAL INJURY, PROPERTY DAMAGE, OR ANY SPECIAL, INCIDENTAL,
CONTINGENT, OR CONSEQUENTIAL DAMAGES OF ANY KIND, RESULTING FROM DEFECTS IN SENSOR OR FOR BREACH OF ANY EXPRESS OR IMPLIED WARRANTY ON THIS
PRODUCT.
1. PRESS TO
RELEASE
HOOK
FIGURE 1
2. LIFT UP
BUTTON
LIGHT LEVEL
T
E
S
T
5
1
5
3
0
TIME DELAY
FIGURE 2