User guide

Menvier40/100 Technical Specification
Page 31
Capacities (Menvier100)
Zones
100 max (with expanders)
Outputs
100 max (with expanders)
Expanders and
Wired Keypads
45 max devices (see note)
Radio Keypads
10 max (two per radio
expander)
External Radio
Sirens
10 max (two per radio
expander)
WAMs
10 max (two per radio
expander, repeater mode
only)
Wards
10
Calendar Set
Timers
10 max
Log capacity
Up to 1,250 events: 1,000
mandatory events, 250 non-
mandatory. Stored in
EEPROM memory, available
for at least 10 years without
power.
User Codes
250 (plus installer code)
Remote controls
250 (one per user)
Radio Hold Up
Devices
250 (one per user)
Proximity tags
250 (one per user)
Note: Wired keypads, wired zone
expanders, and radio zone expanders are
all bus devices. You can connect any
combination of these devices to the bus.
Capacities (Both)
Outputs
16 plug-by communicator
outputs plus 3 wired on
control unit (two transistor
and one relay)
4 transistor based on each
wired expander
8 radio outputs on each
768/769
2 radio outputs on each 762
Radio Keypads
5 max (two per radio
expander)
Loudspeakers
1 on control unit, one per
expander
Plug on
communication
modules
One
Other ports
1 x USB, 1 x Ethernet
Internal Clock
±10 minutes over one year.
Notes:
1. Wired keypads, wired zone expanders,
and radio zone expanders are all bus
devices. You can connect any
combination of these devices to the bus.
2. The system can be used as EITHER a
ward based system OR a part setting
system. When used as a part setting
system there are four setting levels
available: Full Set and Part Sets B, C and
D.
Security
Security
Grade
Grade 2 or 3
Radio
detector
differs
16,777,214 (2
24
-2).
Radio
Supervision
Programmable.
Number of
access codes
100 plus one installer
Access code
differs
10,000 differs with 4 digit
codes.
1,000,000 differs with six
digit codes.
All digits may be any
number 0 to 9.
Code blocking
Blocked for 90s after 10
incorrect codes in series.
Proximity tag
differs
4,294,967,296 (2
32
)
Power Supply
This product complies with the requirements of
EN50131-6 Type A power supply at Grade 3 and
environmental class 2.
Power supply type
A
Mains power supply
requirements
230VAC +10%/-15%,
170mA max, 50Hz.
Total power supply
capacity:
1.5A
(of which 750mA is
used for battery
recharge and 750mA
is available for
powering the
system).
12V Aux supply*:
500mA max
12V Bell supply
500mA max
Comms power
supply*:
400mA max
12V Expander
Bus*:
400mA max
LS connectors
280mA in alarm.
*Note: The ratings given here represent the
maximum current that can be drawn before
triggering over-current protection.
EN50131-6 ratings
The control unit provides space for one
17Ah battery.
Under EN50131-6 for Security Grade 3
installations the required battery standby
time is 60 hours. However, with an ATS4