Instruction Sheet
Instruction Manual/Instrucciones
Questions?/¿Preguntas? 1-800-334-6871 ConsumerProducts@cooperlighting.com
1
•Disassemblyofyourxturewillvoidthewarranty.
•Yourxtureisprewiredandpreassembledforeasyinstallation.
•MINIMUM90°CSUPPLYCONDUCTORS.
•ThisdevicecomplieswithPart15oftheFCCRules.Operationissubjecttothefollowing
twoconditions:(1)Thisdevicemaynotcauseharmfulinterference,and(2)thisdevicemust
acceptanyinterferencereceived,includinginterferencethatmaycauseundesiredoperation.
UnderPart15oftheFCCRules,anychangesormodicationstothemotiondetector
describedinthisinstructionsheetthatarenotexpresslyapprovedbyCooperLighting,LLC
couldvoidtheuser’sauthoritytooperatetheequipment.
NOTE:ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassB
digitaldevice,pursuanttoPart15oftheFCCRules.Theselimitsaredesignedtoprovide
reasonableprotectionagainstharmfulinterferenceinaresidentialinstallation.This
equipmentgenerates,usesandcanradiateradiofrequencyenergyandifnotinstalled
andusedinaccordancewiththeinstructions,maycauseharmfulinterferencetoradio
communications.However,thereisnoguaranteethatinterferencewillnotoccurinaparticular
installation.Ifthisequipmentdoescauseharmfulinterferencetoradioortelevisionreception,
whichcanbedeterminedbyturningtheequipmentoffandon,theuserisencouragedtotryto
correcttheinterferencebyoneormoreofthefollowingmeasures:
-Reorientorrelocatethereceivingantenna.
-Increasetheseparationbetweentheequipmentandreceiver.
-Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthereceiver
isconnected.
-Consultthedealeroranexperiencedradio/TVtechnicianforhelp.
WARNING: FCC Regulations state that any unauthorized changes or modifications
to this equipment not expressly approved by the manufacturer could void the user’s
authorization to operate this equipment.
SAVE THESE INSTRUCTIONS.
FOR BEST RESULTS
•Installthemotionsensor/transmitter8-12feet
abovetheground.(Motionsensorislesssensitive
above12feet.)
•Locatemotionsensorsomotionmovesacross
detectionzone(Fig.1).
•Locatesensorawayfromheatproducingsourcesto
preventfalsetriggering.Alsobeverycarefulnotto
includeobjectssuchaswindows,whitewallsand
waterinthedetectionzone.
•Locatesensorawayfrommovingobjectssuchas
trees,largeshrubsandstreettrafc.
•Donotinstallmorethanonemotionactivated
oodlightononewallswitch.
MOUNTING AND WIRING YOUR FIXTURE
WARNING: Risk of electric shock. Disconnect
power at fuse or circuit breaker before installing
or servicing.
PACKAGING CONTENTS/CONTENIDO DEL PAQUETE
ITEMS REQUIRED
(Purchase separately)
•Phillipsscrewdriver
•Outdoorweatherproofsiliconecaulking
•(2)100watt(MAX)PAR38oodlightbulbs
NOTE:Thisxturewasdesignedtoworkwithupto150wattmaximumPARhalogenood
bulbs.Forimprovedenergyefciency,lowerwattagePARhalogenoodbulbsmaybeused.
CompactFluorescent(CFL)bulbscontainelectronicswhichmayinterferewiththemotion
sensingfunctionofyourxtureandarenotrecommended.TomeetENERGYSTAR
®
requirements,maximumlampwattagecannotexceed250watts.
HOW IT WORKS
Yourmotionactivatedoodlightsensesheatimagesfrom
objectssuchaspeople,largeanimalsandautomobileengines.
Whenmotionisdetected,thelightswillautomaticallyturn
on.Oncemotionhasstopped,thelightswillturnoffaftera
preselectedtimedelay.Yourmotionactivatedoodlightmay
alsobeusedasastandardoodlight.
WARNINGS AND CAUTIONS
•Readtheseinstructions.
•Keeptheseinstructions.
•Heedallwarnings.
•Followallinstructions.
•Foroutdooruseonly.
•cULusLISTEDforwetlocations.
•Connectxturetoa120volt,60Hzpowersource.Anyotherconnectionvoidsthewarranty.
•Fixtureshouldbemountedtoagroundedrecessedmountedstandardjunctionboxmarked
foruseinwetlocations.
•Suitableforwallmountoreavemountonly.NOTsuitableforgroundmountinstallation.
•Donotallowsensorheadtotouchlighthousing–maintainatleast1in.spacebetween
xtureandsensor.
•Fixtureshouldbeinstalledbypersonswithexperienceinhouseholdwiringorbyaqualied
electrician.Theelectricalsystem,andthemethodofelectricallyconnectingthexturetoit,
mustbeinaccordancewiththeNationalElectricalCodeandlocalbuildingcodes.
•Alwaysreplacebulbwiththesamewattageorlowerwattagethanincluded.Installinga
bulbofahigherwattagecouldcreatearehazard.Useofahigherwattagebulbwillvoid
thewarranty(maximum150watthalogenbulb).TomeetENERGYSTAR
®
requirements,
maximumlampwattagecannotexceed250watts.
•Forproperoperationandprotectionagainstdamage,themotion
sensorheadadjustmentknobsmustbefacingtheground.
•Keepawayfromammableobjects.Donotpositionxturewithin2in.
ofanycombustiblematerials.
MS245R (Bronze)
MS245RW (White)
A. Motion detector
light fixture
Detector de movimiento
y artefacto de luz
ENGLISH
Upto
70feet
240degrees
I. (2) Reflectors
(2) Reflectores
D. (2) #6 and (2) #8 mounting screws
(use the size that fits your junction box)
(2) Tornillos #6 y (2) tornillos #8 de montaje
(utilice el tamaño que mejor se adecue a
su caja de conexión)
B. Coverplate gasket
Junta de la placa
de cubierta
E. (3) Wire nuts
(3) Tuercas para alambre
C. (2) Lampholder gaskets
(2) Juntas obturadoras
del receptáculo
F. Color-matched
center hole plug
Tapón para agujero
central de color
coincidente
G. Center bolt
Perno central
H. Mounting bracket
Soporte de montaje
Fig.1