HD-SDI High Speed Dome Camera Series USER’S MANUAL Note: ※Please read the operation manual carefully before installing and using this unit 1
Warning: To reduce the risk of fire or electric shock, do not expose this product to rain or moisture. Do not insert any metallic objects through the bentilation grills or other openings on the equipment. This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit. CAUTION: TO REDUCE THE RISK OF ELECTROIC SHOCK, DO NOT REMOVE COVER(OR BACK). NO USER SERVICEABLE PARTS INSIDE.
Content Warning .......................................................................................... Error! Bookmark not defined. Content ........................................................................................... Error! Bookmark not defined. 1.Points for attention ....................................................................... Error! Bookmark not defined. 2.Function Description .................................................................... Error! Bookmark not defined.
1. Please read the operation manual carefully before installing and operating the product. 2. The product takes power supply of AC24V. The rated input voltage of the camera is marked on the base or other corresponding place. 3. During the course of transportation, storage and installation, the product should be avoided from incorrect operations such as heavy pressing, strong vibration etc., which can cause damage of product as there are sophisticated optical and electronic devices inside the machine. 4.
II. Functions Description 1. Integrated speed-variable PAN/TILT a. Turning 360°horizontally and continuously with unlimited positions and an adjustable speed from 0 -- 300°/s; turning 0 - 90°vertically with a speed up to 120°/s. b. Running stably at low speed with super lower noise. Pictures have no shaking. c. the location precision up to ±0.1°. d. 6 programmable tracks, 4 scanning tracks,1 pattern track. e. Idle ptorection and power-off memory function. f.
III.
IV.Installation 1.Conect description 1.1 4 kinds of bracket installation for outdoor speed dome:wall mount, cornet mount, ceilling mount, pole mount. 1.1.1 Wall mount Check the wall and make sure it’s firm. The bearing weight is more than 8 times of the speed dome weight. a. Label installation position b. Install the bracket c. Assemble the speed dome d. Fix the speed dome e.
1.1.2 Corner mount Check the wall and make sure it’s firm. The bearing weight is more than 8 times of the speed dome weight. f. Label installation position a. Install the base Make the power cable, RS485 cable and video cable through the hole of base g. Install the bracket b. The same way of wall mount installation 1.1.3 Pole mount The diameter of pillar is 130-150mm( 5.12”~6) a. Install the base b. Install the bracket c. The same way of wall mount installation 1.1.
b. Make the cable through the hole and fix the base on the ceilling. Note: if install outdoor, please coat silicone gel on the base. d. Install the bracket d. Install the dome housing Note:if outdoor, please use silicone gel and rubber belt Note, if outdoor, please use waterproof tapes, if the ceilling is too low, we may install on the base directly. e. Connection of cables According to the connection identifier 1.2. Installation for indoor speed dome. 1.2.
1.2.3 Take out the plug of the dome camera and connect external power supply, RS485 and VF wires as per marks on the plug. Take care that the power supply of the spherical camera and adopt the particular power supply which is provided with the dome camera. 1.2.4 Take out the mounting base from the spherical camera, thread the connecting wire from behind through the central hole of the base. Fix the base by three screws on the ceiling as per the drawing, and connect the wire with the ball.
2.Product size Fig 4.1 3.Connection identifier Fig 4.
V. Operation Introduction 1. Basic Operation of the Menu 1.1 Open the main menu of the setup by the keyboard or the matrix via the operation “Call No. 64 preset position 1.2 When the menu is displayed on the screen, operate “TILT UP”, “TILT DOWN” to move the cursor to the option to be set, operate “PAN LEFT”, “PAN RIGHT” to modify the content or the order to enter this option. 1.3 All setups on the menu couldn’t be lost even power failure 2. Setup of the Menu 1. 1.1 MAIN MENU 1.1.1 SYSTEM SETUP. 1.1.
1.1.8 EXIT: to quit the main menu. 1.2 SYSTEM SETUP 1.2.1 SYSTEM INFORMATION: to display the system information. 1.2.2 AUTO FLIP: to ON/OFF the dome 180°auto flip. 1.2.3 PROP PAN SPD: to ON/OFF the proportional pan function. SYSTEM SETUP 1.SYSTEM INFORMATION 2.AUTO FLIP: ON 3.PROP PAN SPD: ON 4.RESERVED: N/A 5. 6.RETURN 1.2.4 RESERVED:This function setting also kept for this products. 1.2.5 ALARM SETUP: 1.2.5.1 ALARM NO: N/A 1.2.5.2 ACTION: N/A 1.2.5.3 ALARM: 1.2.5.
TOP/BOTTOM. 1.3.2.3 RETURN: to return to the DISPLAY SETUP menu. 1.3.3 PRESET LABEL: to enter the PRESET LABEL submenu. 1.3.3.1 DISPLAY: to ON/OFF the display of the preset label. If it is ON, the preset label will be displayed on the left of the monitor when the preset position is setting. 1.3.3.2 POSITION: to set the display position of the preset label: TOP-at the top of the monitor, BOTTON- at the bottom of the monitor. 1.3.3.3 RETURN: to return to the DISPLAY SETUP menu. 1.3.
Manual/Automatic. When camera screen is opened under automatic state, ASS displays on screen. (Only sony camera has this function) 1.4.8 WB/AE SETUP. 1.4.8.1 AE MODE: to set the automatic exposure to MANU/AUTO/SHUTTER mode; SHTTER: it is only available at the AE MODE is SHUTTER. 1.4.8.2 WB MODE: to set the white balance mode: ATW / MANUAL / AUTO / INDOOR / OUTDOOR / ONEPUSH; R GAIN: it is only available for pulsing red at the WB MODE Is MANUAL.
characters at most, they are 0-9, A-Z, blank and special characters including 〈 = 〉?,@\+、-./ ]etc. Notes: the first letter must be from 0-9 or A-Z, in case that, it stands for canceling the preset position topic. When testing the preset position, it only display “NO.XXX”, not display the topic. 1.5.1.3 CLR LABEL: to clear the preset label. 1.5.1.4 RETURN: to return to the PROGRAM SETUP submenu. 1.5.2 AUTO SCAN: to enter the Auto Scanning submenu: 1.5.2.
1.5.3.1 PATROL NO: to set the patrol number. 1.5.3.2 EDIT PATROL: to set the parameter of the patrol, after enter this item, the monitor is as following: Both top and bottom lines display prompt and information of each patrol is displayed on the middle of the screen. Data of 2 Patrol points appears on one line. And to press PAN LEFT/RIGHT to move the cursor, to press TILT UP/DOWN to modify the data, to press “CLOSE” to save and quit the edit state. 1.5.3.
1.5.5.2 CLEAR ALL SCAN: to clear all the scanning. 1.5.5.3 CLEAR ALL PATROLS: to clear all the patrols. 1.5.5.4 CLEAR ALL PATTERNS: to clear all the patterns. 1.5.5.5 RETURN: to return to the PREGRAM SETUP menu. 1.5.5.6 EDIT DOME LABEL: To edit the dome label. Set a label for each dome, the label is make up of 10 characters, and the optional character is the same as 2.5.1.2. 2.5.7 RETURN: to return to the MAIN MENU. 1.6 PRIVACY MASK: 1.6.1 PRIVACY MASK: to set the privacy number.
the manual control, PATROL 1 is the patrol No.1, SCAN 1 is the scanning No.1 and the PATT 1 is the pattern No.1. 1.7.1.3 PARK TIME: to set the park time of the dome camera, it is mean how long the dome camera will be back to the HOME. The time from 1-99 minutes. 1.7.1.4 PWR RESUME: to ON/OFF the function, which the dome camera will be back to the scene before the power off. 1.7.1.5 RETURN: to return to the ADVANCE SETUP Menu. 1.7.2 PASSWORD: to enter the password setting menu.
under AUTO condition. 2.7.4.3 Temperature Fahrenheit / Celsius display switch. 2.7.4.4 TEMP DISPLAY: to ON/OFF the display of the temperature. 2.7.4.5 RETURN: to return the ADVANCE SETUP menu. 2.7.5 LANGUAGN: to select the language. 2.7.6 SET NORTH POSITION. 2.8 EXIT: to exit the main menu. 3. Code switch setting 3.1 Code Switch position Fig 5.1 3.2 Setup of Coding Switch of Dome Camera As shown in Figure 5.1, SW1 is used to set address of the dome camera from 1 – 1023.
switches of some addresses.
PELCO-P OFF ON OFF OFF OFF OFF Fig 5.2 3.4. Setup of the Baud Rate of Communication As shown of figure 5.1, J8 set the protocol and baut rate of speed dome. DIP-4to DIP-1 to choose the protocol, max 4 selection of baut rate.If the baut rate of contrller isn’t standard, please adjust the baut rate the same with it. Baut rate Bate rate set DIP-1 DIP-2 DIP-3 DIP-4 DIP-5 DIP-6 2400bps OFF OFF 4800bps ON OFF 9600bps OFF ON 19200bps ON ON 3.5.
98 Reserved Reserved 99 If the built-in camera is YOKO231, please set the 99 preset in advance, re-start the speed dome, camera will work correctly.
VI.Technical data table Model CD55-SDI Cam characteristics Sensor 1/2.8” 200W Exmor@ CMOS sensor Zoom 20X optic/12X digital zoom Lens F=4.7mm-94mm, f1.6-3.5,angle: 55.4°to 2.9° Resolution 1080P/30FPS,1080P/25FPS Min illumination Day:1.7LUX/1/30sec,night(ICR)0.
VII.
Appendix : Lightning Proof and Surge Signal Proof The product adopts TVS lightning proof technology to prevent from damage by lightning strike below 1500 W and impulse signals such as surge; but it is also necessary to abide by the following precautions to ensure electrical safety based on practical circumstances: Keep the communication cables at least 50 meters away from high voltage equipment or cables. Make outdoor cable laying-out under eaves as possible as you can.
Appendix : The Cleaning of Clear Down Cover To obtain constant clear videos, user should clean the down cover periodically. Be cautious when cleaning. Hold the down cover ring only to avoid direct touch to the acrylic down cover. The acid sweat mark of fingerprint will corrode the coating of down cover and scratch on down cover will cause vague images. Use soft dry cloth or the substitute to clean the inner and outer surfaces. For hard contamination, use neutral detergent.
A+ . . . . . BD A+ B. . . . . 120Ω M ain controller 1# 2# 3# 120Ω 31# Figure 21 The connection of 120Ω termination resistor: The termination resistor is ready on the Protocol PCB. There are two kinds of connection. Refer to the Protocol PCB jumper setting form (refer to Picture 2). 1) In the Picture it is the factory default connection. The jumper is seated on Pin2&Pin3 and the termination resistor is not connected.
MC2080 B- 120Ω 1# 120Ω 2# . . . . A+ 16# 120Ω < Fig.