Installation/Operation Manual for HD Video Speed Dome Camera V1.
Operation Manual for Intelligent Speed Dome Camera I. Points for Attention 1. Please read the operation manual carefully before installing and operating the product. 2. The product takes power supply of AC24V. The rated input voltage of the camera is marked on the base or other corresponding place. 3. During the course of transportation, storage and installation, the product should be avoided from incorrect operations such as heavy pressing, strong vibration etc.
Operation Manual for Intelligent Speed Dome Camera II. Description of Functions The intelligent dome camera is a hi-tech CCTV product which incorporates high-clarity color camera, panoramic speed-variable PAN/TILT, multifunctional decoder, CPU processor, memory chip into a whole. It can largely reduce connection and installation processes of components in the system, rise up reliability of the system and facilitate installation and maintenance.
Operation Manual for Intelligent Speed Dome Camera Principle: we call “hard ID (HID)” that setting by the Dip-switcher, and “Soft ID (SID) that setting by the Long-distance address modify. The HID and the SID are same in leaving factory. For example: Camera No.001, HID=SID=001, we change the SID=002 by RS485, so we should select the No. 002 to control it, and the SID address will be remember after shut. And if we change the HID=003 by Dip-switcher, the HID and the SID will be both change to HID=SID=003 4.
Operation Manual for Intelligent Speed Dome Camera 2.1.2 DISPLAY SETUP: to enter the submenu of display of the screen by which ID display, title display of preset point and display of camera screen can be set. MAINMENU 2.1.3 CAMERA SETUP: to enter the submenu of setup of normal data of camera. 2.1.4 MOTTON SETUP: to enter the setup of enhanced function of dome camera. 1. 2. 3. 4. 5. 6. 7.SYSTEM RESET 8.EXIT 2.
Operation Manual for Intelligent Speed Dome Camera 2.2.5.4 2.2.6 RETURN: to return to the SYSTEM SETUP menu. RETURN: to return to the main menu. 2.3 DISPLAY SETUP 2.3.1 CAMERA ID: when it is set at ON, address of dome camera appears on the screen such as “CAM 001”. The default setting is ON. 2.3.1.1 DISPLAY: to ON/OFF the dome address. 2.3.1.
Operation Manual for Intelligent Speed Dome Camera 2.3.4.2 POSITION: to set the display position of the dome label: TOP-at the top of the monitor, BOTTON- at the bottom of the monitor. 2.3.4.3 RETURN: to return to the DISPLAY SETUP menu. 2.3.5 RETURN: to return to MAIN MENU. 2.4 CAMERA SEUP: If setting camera parameter is N/A, it Me ansthe camera can not support this function. 2.4.1 D-ZOOM: to ON/OFF the digital zoom. 2.4.2 DISPLAY: to ON/OFF the display of the camera information. 2.4.
Operation Manual for Intelligent Speed Dome Camera 2.4.8.6 AMOUNT: the value of exposure-compensation:-7 - +7. 2.4.8.7 RETURN: to return to the WB/AE SETUP menu. 2.4.9 RETURN: to return to the MAIN MANU. 2.5 MOTION SETUP 2.5.1 PRESETS: to enter the Preset Position submenu. 2.5.1.1 PRESET NO: to edit the preset number. 2.5.1.2 EDIT LABEL: to edit the preset label. After entering the edit mode, 1-128 present positions.
Operation Manual for Intelligent Speed Dome Camera 2.5.2.4 SET END LIMIT: to set the end position of the scanning. After the user enter this item, to use the joystick to move the dome camera and press “CLOSE” to save the current position. 2.5.2.5 RUN SCAN: to run the scanning function, Please set the start and end position first. And if the start and end position are the same. The dome camera will scanning for 360°。To press “CLOSE” to exit. 2.5.2.
Operation Manual for Intelligent Speed Dome Camera 2.5.4.2 RECORD PATTERN: to record the pattern, and press “CLOSE” to exit. 2.5.4.3 RUN PATTERN: to run the pattern, and will quit the menu automatically, and any move of the joystick will stop this function. 2.5.4.4 CLEAR PATTERN: to clear the setting of the pattern. 2.5.4.5 RETURN: 2.5.5 to return to the superior menu. CLEAR: to enter the CLEAR submenu. 2.5.5.1 CLEAR ALL PRELABEL: to clear all the preset positions. 2.5.5.
Operation Manual for Intelligent Speed Dome Camera 2.7.1.2 HOME ACTION: to set the auto home point. For example: if the user want to set one scene to be the HOME, just set the dome camera to this scene, and set it to be the preset No:3, then open this menu, set the HOME ACTION to be “3”. And don’t forget to set the AUTO HOME to be ON. The HOME ACTION could be the preset “1-50”, RESUME, PATROL 1, SCAN 1, PATT 1.
Operation Manual for Intelligent Speed Dome Camera SETTING menu. 2.7.4 FAN CONTROL: to enter the fan control setting submenu. 2.7.4.1 FAN: to set the work condition of the fan: ON / OFF / AUTO. 2.7.4.2 OPEN TEMP: to set the work temperature of the fan under AUTO condition. 2.7.4.3 Temperature Fahrenheit / Celsius display switch. 2.7.4.4 TEMP DISPLAY: to ON/OFF the display of the temperature. 2.7.4.5 RETURN: to return the ADVANCE SETUP menu. 2.7.5 LANGUAGN: to select the language. 2.7.
Operation Manual for Intelligent Speed Dome Camera SW2 SW1 ON 1 2 3 ON 1 2 3 4 5 JP 1 6 2 3 4 5 6 7 8 9 10 120Ω term inalresistor is opened forR S485 bus 1 2 3 Address Set Protocol Set SW2: DIP1--DIP4 Select Protocol SW2: DIP5--DIP6 Select Baud Rate JP 120Ω term inal resistor is connected on R S485 B us Bracket for fixed camera 2. Figure 2 Setup of Coding Switch of Dome Camera. As shown in Figure 2, SW1 is used to set address of the dome camera from 1 – 1023.
Operation Manual for Intelligent Speed Dome Camera maximum.
Operation Manual for Intelligent Speed Dome Camera 9600bps OFF ON 19200bps ON ON 5. Selection of the Terminal Resistor of the Dome Camera. As shown in Figure 2, JP is the select switch of the 120 Ω terminal resistor on the bus RS485, on which only one terminal resistor of the dome camera at the farthest end can be connected, while the terminal resistors of other devices should be opened. 6. Shortcut control function Preset Set Preset 1 Reserved 64 Close the menu 90 Reserved 91 1080i/59.
Operation Manual for Intelligent Speed Dome Camera Figure 4 b) In-Ceiling Installation 2. Figure 5 Steps of Installation (taking wall-mounting as example) 1) Unpacking the carton and carefully take out the dome camera and its attachments. 2) Rotate the vitreous cover counterclockwise and take out it. (see Figure 6) Note: It can be ignored the steps 2,3,4,5 while the protocol and address are matching with the controller. 3) Take out the black liner.
Operation Manual for Intelligent Speed Dome Camera Takedown the black liner Open Figure 6 5) Figure 7 Fix the black liner (see Figure 8). Fixed the black liner Figure 8 6) Take out the cover of the wall-installed bracket.(Figure9) 7) Take out system control wires from the bracket(Figure 10). 8) Fix the bracket on the wall(Figure11).
Operation Manual for Intelligent Speed Dome Camera MARK OPEN LOCK PUSH Figure 12 Figure 13 11) Rotate the vitreous cover clockwise and mount it(Figure 14) Figure 14 12) Connect the control wires of the system as per Figure 15.
Operation Manual for Intelligent Speed Dome Camera arrow until it is clicked and tightened(Figure17). 4) And then, please fix the dome to the bracket with bolts.(Figure18). Figure16 1) 2) 3) 4) 5) Ⅴ. Figure17 Figure18 4.To ensure a smooth and successful installation, you must: Have electrical work comply with latest national electrical code, national fire code, and all applicable local codes and ordinances. Coordinate work with other trades to avoid interference.
Operation Manual for Intelligent Speed Dome Camera Precision ±0.1° Control mode RS485 Baud Rate 2400/4800/9600/19200 bps Fan & heater Fan & heater auto-start (only outdoor dome) Environment temp Indoor dome:-5℃ — +45℃ Outdoor dome –35℃ -- +55℃ 2、 Camera Optional data table Effective picture elements Video signal HD:1080i/59.94, 1080i/50,720p/59.94,720p/50 SD:NTSC(CROP),NTSC(SQUEEZE),PAL(CROP),PAL(SQUEEZE) 10X zoom(F1.8 to F2.1) Lens F=5.
Operation Manual for Intelligent Speed Dome Camera The product adopts TVS lightning proof technology to prevent from damage by lightning strike below 1500 W and impulse signals such as surge; but it is also necessary to abide by the following precautions to ensure electrical safety based on practical circumstances: z Keep the communication cables at least 50 meters away from high voltage equipment or cables. z Make outdoor cable laying-out under eaves as possible as you can.
Operation Manual for Intelligent Speed Dome Camera As specified by RS485 standards, RS485 Bus is of half-duplex data transmission cables with characteristic impedance as 120Ω. The maximum load capacity is 32 unit loads (including main controller and controlled equipment). 2. Transmission distances of RS485 Bus When user selects the 0.
Operation Manual for Intelligent Speed Dome Camera Figure 22 In such circumstances the factory recommends the usage of DR-HB16 RS485 distributor. The distributor can change the star configuration connection to the mode of connection stipulated in the RS485 standards. The new connection achieves reliable data transmission (refer to Figure 23). MC2080 B- 120Ω 1# 120Ω 2# . . . .
Operation Manual for Intelligent Speed Dome Camera 60 47(14) 75(22) 119(36) 301(91) 70 40(12) 64(19) 102(31) 258(78) 80 35(10) 56(17) 89(27) 226(68) 90 31(9) 50(15) 79(24) 201(61) 100 28(8) 45(13) 71(21) 181(55) 110 25(7) 41(12) 65(19) 164(49) 120 23(7) 37(11) 59(17) 150(45) 130 21(6) 34(10) 55(16) 139(42) 140 20(6) 32(9) 51(15) 129(39) 150 18(5) 30(9) 47(14) 120(36) 160 17(5) 28(8) 44(13) 113(34) 170 16(4) 26(7) 42(12) 106(32) 180 15(4) 25(7) 3
Operation Manual for Intelligent Speed Dome Camera 0.250 30 33 0.04909 0.290 29 31 0.06605 0.330 28 30 0.08553 0.350 27 29 0.09621 0.400 26 28 0.1237 0.450 25 0.560 24 24 0.2463 0.600 23 23 0.2827 0.710 22 22 0.3958 0.750 21 0.800 20 21 0.5027 0.900 19 20 0.6362 1.000 18 19 0.7854 1.250 16 18 1.2266 1.500 15 2.000 12 0.1602 0.4417 1.7665 14 3.1420 2.500 4.9080 3.000 7.