Instruction Manual

Operation Manual for Intelligent Speed Dome Camera
8
2.5.2.4 SET END LIMIT: to set the end position of the scanning. After the user enter this
item, to use the joystick to move the dome camera and press “CLOSE” to save the
current position.
2.5.2.5 RUN SCAN: to run the scanning function, Please set the start and end position first.
And if the start and end position are the same. The dome
camera will scanning for 360°。To press “CLOSE” to exit.
2.5.2.6 CLEAR SCAN: the clear the setting of the scanning, to
press “CLOSE” to exit.
2.5.2.7 RETURN: to return to the PROGRAM SETUP menu.
2.5.3 PATROLS: to enter the submenu to set the patrols.
2.5.3.1 PATROL NO: to set the patrol number.
2.5.3.2 EDIT PATROL: to set the parameter of the patrol, after enter
this item, the monitor is as following:
Both top and bottom lines display prompt and information of each patrol is
displayed on the middle of the screen. Data of 2 Patrol points appears on one line.
And to press PAN LEFT/RIGHT to move the cursor, to press TILT UP/DOWN to
modify the data, to press “CLOSE” to save and quit the edit state.
2.5.3.3 RUN PATROL: to run the patrol, press “CLOSE” to exit.
2.5.3.4 CLEAR PATROL: to clear the patrol.
2.5.3.5 RETURN: to return to the PROGRAM SETUP menu.
2.5.4 PATTERNS: to enter the PATTERN setting submenu.
2.5.4.1 PATTERNS: to edit the pattern number. No 1-3 for optional.