User guide
Xenus XTL User Guide    Quick Setup with CME 2 
Copley Controls Corp.  97 
5.7.1.4  In position mode, set the Trajectory Limits described below: 
Option Description 
Max Velocity  Maximum trajectory velocity. Max value may depend upon the back EMF and the 
Max feedback count. Min:0. Default: 0.25 x motor velocity limit. 
Max Accel  Maximum trajectory acceleration. Max value may depend upon the load inertia and 
peak current. Min:0. Default: 0.5 x velocity loop Accel. Limit value. 
Setting to zero will disable trajectory limits. 
Max Decel  Maximum trajectory deceleration. Max value may depend upon the load inertia and 
peak current. Min:0. Default: 0.5 x velocity loop Accel. Limit value. 
Abort Decel  Deceleration rate used by the trajectory generator when motion is aborted. Min:0. 
Default: 0.5 x velocity loop Accel. Limit value. 
5.7.1.5  Click Close. 
5.7.1.6  On the Main screen, click Save to Flash.
5.7.1.7  Proceed to Auto Phase (p. 102).










