User guide
Xenus XTL User Guide    Using CME 2 
Copley Controls Corp.  121 
6.1.3: Main Menu Overview 
The CME 2 Main Menu choices are described below. 
Menu  Selection  Description  For More Information 
Save Amplifier Data  Saves contents of amplifier’s RAM to a 
disk file. 
Restore Amplifier 
Data 
Restores contents of an amplifier file 
from disk to amplifier RAM. 
Manage Amplifier and Motor Data (p. 
125). 
Restore CVM 
Control Program 
Prompts for a Copley Virtual Machine 
program file. The program in this file will 
replace the current program in flash. 
This procedure also results in the setting 
of the Indexer 2 Program option Enable 
Control Program on Startup. This 
configures the program to auto start 
when the amplifier is powered up or 
reset. 
Copley Indexer 2 Program User 
Guide. 
Restore Cam Tables  Prompts for a saved Cam Table file (.cct 
file). All tables in amplifier flash will be 
replaced by the ones in this file. 
See Copley Camming Users Guide. 
File 
Exit  Closes CME 2. Prompts for data-saving decision. 
Basic Setup  Opens Basic Setup screen.  Basic Setup (p. 73). 
Control Panel  Opens Control Panel.  Control Panel (p. 130). 
Auto Phase  Opens Auto Phase tool.  Auto Phase (p. 102). 
Scope Opens Scope.  CME 2 User Guide. 
Error Log  Opens Error Log. CME 2 User Guide. 
Amplifier Properties  Displays basic amplifier properties.   
CAN/DeviceNet 
Configuration 
Opens the CAN or DeviceNet 
Configuration screen. 
Rename  Prompts for new amplifier name.  Renaming an Amplifier (p. 124). 
Amplifier 
Auto Tune  Auto Tune for Linear Servo Motors.  CME 2 User Guide. 
Communications 
Wizard 
Starts sequence of prompts to set up 
serial port. 
Serial Port Setup (p. 69). 
Communications Log  Opens Communications Log.  CME 2 User Guide. 
Download Firmware  Starts prompts to download new 
firmware image from disk to amplifier. 
Downloading Firmware (p. 128). 
Download CPLD 
Program 
Starts prompts to download PLD code 
from disk to amplifier. 
Download FPGA 
Program 
Starts prompts to download FPGA code 
from disk to amplifier. 
Firmware Recovery  Starts prompts to recover amplifier when 
a firmware download was interrupted. 
CME 2 User Guide. 
Manual Phase  Opens Manual Phase tool.  CME 2 User Guide. 
View Scope Files  Opens Trace Viewer window.  CME 2 User Guide. 
I/O Line States  Opens I/O Line States window.   
Tools 
CME 2 Lock/Unlock  Opens screen for locking and unlocking 
CME 2 functionality. 
CME 2 User Guide. 
ASCII Command 
Line 
Opens screen to accept ASCII format 
commands. 
CME 2 User Guide. 
Continued… 