6.6: Home Function 
6.6.1: Overview 
The CME 2 Home function can be used to set and test homing parameters. 
6.6.2: Homing Functions Settings 
6.6.2.1  On Main screen, click Home to open the Homing screen.
6.6.2.2  Select homing options described below. 
Parameter Description 
Software limits: 
Positive 
Software limits: 
Negative 
Position of user-defined travel limits that take effect after homing 
operation. 
Software limits: 
Disable 
Disables the use of software limits by setting both limits to zero. 
Method  Homing method. See Homing Methods in the CME 2 User Guide. 
Direction of Motion  Initial direction of motion for the homing method (Pos or Neg). 
Fast Velocity  The velocity used to find a limit or home switch. Also used when moving to an 
offset position, or a resolver or Servo Tube index position. 
Slow Velocity  The velocity used to find a switch edge, incremental or analog encoder 
index pulse, or hard stop. 
Accel/Decel  The acceleration and deceleration rate used during homing. 
Offset  Execute a move of this distance after the reference is found. Set actual 
position to 0 and call the new position home. 
Current Limit 
Current Delay Time 
Hard stop home is reached when the amplifier outputs the homing Current 
Limit continuously for the time specified in the Delay Time. 
Actual Current  Shows actual current being applied to windings during homing. 
6.6.2.3  Optionally click Home to begin a homing sequence. 
6.6.2.4  To stop the homing sequence before it is completed, click Stop.
6.6.2.5  Click Save to save the settings to flash memory. Click Exit to close the screen. 