User guide
Xenus XTL User Guide    Xenus Filter 
Copley Controls Corp.  157 
 D.2: XTL-FA-01 Edge Filter Specifications 
Voltage, maximum  373 Vdc 
Input 
Current, maximum  20 Adc 
Voltage, maximum  373 Vdc 
Output 
Current, maximum  20 Adc 
Peak Current/Peak Current Time  40 Adc for 1 second 
Rise/Fall Time  500 nS (typical) 
Differential Mode Inductance  82 PH per phase, 162 uH phase-phase (nominal) 
Common Mode Inductance  220 PH (nominal) 
Nominal Resistance  27 milliohms per leg, 54 milliohms phase-phase (nominal) 
Agency Approvals  UL508C, EN60204, RoHS 
D.3: Thermal Considerations 
Cooling Requirements 
When used with XTL-230-18 or XTL 230-36 amplifiers, the XTL-FA-01 operates below maximum 
temperature values, and thus requires no cooling fan. 
When used with XTL-40 amplifiers running continuous currents greater than 12 Adc, 
the XTL-FA-01 should be cooled with an external fan. The fan should have a flow rate of at least 
110 CFM. The filter has been tested using the Comair Rotron MD24B2 24 Vdc powered fan. 
Fan Mounting Guidelines 
Most of the filter’s heat is transferred to ambient air, rather than through the heat plate. Thus, it is 
very important to mount the filter and fan in such a way that the fan can blow up through the filter’s 
cover slots. Mount the filter on edge and mount the fan below it so that it blows up through the 
cover slots. 
There is no heatsink option for the XTL-FA-01 edge filter. 