User guide
Xenus XTL User Guide    Xenus Filter 
Copley Controls Corp.  161 
D.5.3: Cable Notes 
1 Keep the Edge Filter J1 to Xenus J2 cable as short as possible. A typical length is 7 inches. 
2 To reduce noise, twisted shielded cable must be used and the signal cables should not be 
bundled in the same conduit. 
D.5.4: Input (J1) From Amplifier 
Mating Connector 
Description  Euro-style, 5 position, 5.0 mm pluggable female terminal block 
Manufacturer PN  Wago 51118042 or 721-105/026-047/RN01-0000 
Wire Size  22 - 12 AWG 
Recommended Wire  12 AWG, 600 V 
(Shielded cable used for CE compliance) 
Wire Insertion/Extraction Tool  Wago 231-131 
Connector and tool are included in connector kit XTL-FK. 
Pin Description 
Pin Signal Function 
1 Ground  Chassis ground and cable shield 
2 Phase W  Phase W input from amplifier 
3 Phase V  Phase V input from amplifier (use for DC motor connection) 
4 Phase U  Phase U input from amplifier (use for DC motor connection) 
5 --- No connection 
D.5.5: Output (J2) To Motor 
Mating Connector 
Description  Euro-style, 4 position, 5.0 mm pluggable female terminal block. 
Manufacturer PN  Wago 51118008 or 721-104/026-047/RN01-0000 
Wire Size  22 - 12 AWG 
Recommended Wire  12 AWG, 600 V 
(Shielded cable used for CE compliance) 
Wire Insertion/Extraction Tool  Wago 231-131 
Connector and tool are included in connector kit XTL-FK. 
Pin Description 
Pin Signal Function 
1 Ground  Chassis ground and cable shield 
2 Phase W  Phase W output to motor 
3 Phase V  Phase V output to motor (use for DC motor connection) 
4 Phase U  Phase U output to motor (use for DC motor connection) 