4.1: General Wiring Instructions 
4.1.1: Electrical Codes and Warnings 
Be sure that all wiring complies with the National Electrical Code (NEC) or its national equivalent, 
and all prevailing local codes. 
DANGER: Hazardous voltages. 
!
DANGER 
Exercise caution when installing and adjusting. 
Failure to heed this warning can cause equipment damage, injury, or death. 
Risk of electric shock. 
!
DANGER 
High-voltage circuits on J1, J2, and J3 are connected to mains power. 
Failure to heed this warning can cause equipment damage, injury, or death. 
Do not ground mains-connected circuits. 
!
WARNING
With the exception of the ground pins on J1, J2, and J3, all of the other circuits on 
these connectors are mains-connected and must never be grounded. 
Failure to heed this warning can cause equipment damage. 
Do not plug or unplug connectors with power applied. 
!
WARNING
The connecting or disconnecting of cables while the amplifier has 24Vdc and/or 
mains power applied is not recommended. 
Failure to heed this warning may cause equipment damage. 
4.1.2: Grounding Considerations 
Primary Grounding Functions 
A grounding system has three primary functions: safety, voltage-reference, and shielding. 
J1-3 Primary Ground 
The primary ground at J1-3 is the safety ground and is intended to carry the fault currents from the 
mains in the case of an internal failure or short-circuit of electronic components. This ground is 
connected to the amplifier chassis. Wiring to this ground should be done using the same gauge 
wire as that used for the mains. This wire is a “bonding”’ conductor that should be connected to an 
earthed ground point and must not pass through any circuit interrupting devices. 
The pin on the amplifier at J1-3 is longer than the other pins on J1, giving it a first-make, last-
break action so that the amplifier chassis is never ungrounded when the mains power is 
connected. 