User guide
Xenus XTL User Guide    Quick Setup with CME 2 
Copley Controls Corp.  71 
5.3: Prerequisites 
5.3.1: Hardware and Equipment 
5.3.1.1  Verify that +24 Vdc power is OFF and AC power is OFF. 
5.3.1.2  Verify wiring and connections. 
Ensure the following connections are wired according to the guidelines in 
Wiring (p. 45).
1 J8 "FDBCK" motor signals
2 J2 "U V W Earth" motor power 
3 J7 "CNTRL" control signals 
4 J4 "+24 Vdc, BRAKE" required +24 Vdc (power OFF) 
5 J5 "RS-232" PC serial link 
6 J1 "L1 L2 L3 Earth" line power (power OFF) 
5.3.1.3  Secure the motor: 
1 Make sure motor is securely fastened. 
2 Make sure that no load is connected to the motor. 
5.3.1.4  Apply +24 Vdc to the amplifier’s J4 connection. 
(Do NOT apply AC voltage to the amplifier at this point.) 
Risk of unexpected or uncontrolled motion with CME 2 in CAN or DeviceNet 
mode. 
!
DANGER 
CME 2 can be used while the amplifier is under CAN or DeviceNet control. However, 
some extreme changes made with CME 2 could cause unexpected or uncontrolled 
motion. 
Failure to heed this warning can cause equipment damage, injury, or death. 