5.6.7: Custom Digital Output Settings: Position Triggered Output 
Any of the amplifier’s digital outputs can be programmed to respond in certain ways to the position of 
the controlled axis. The output goes active when the axis position meets the specified criteria. 
5.6.7.1 
5.6.7.2   Choose Custom Position Triggered Output for an output and then click Configure 
Custom to open the In Position Configuration screen. 
5.6.7.3  Select one of the configurations described below and enter appropriate values for the 
parameters. 
Configuration
Description and Parameters 
In Position 
Window 
Activates the output while the axis is in the window between the programmed Upper and 
Lower positions. 
Trigger at 
Position 
Activates the output for the programmed Time when the axis travels through the 
programmed Position.
Trigger Positive 
Motion 
Activates the output for the programmed Time when the axis travels in the positive direction 
through the programmed Position.
Trigger 
Negative Motion 
Activates the output for the programmed Time when the axis travels in the negative 
direction through the programmed Position.
5.6.7.4  Choose Output Active High to have the output go high when active or Output Active Low to 
have the output go low when active. 
5.6.7.5  Choose Use Actual Position (the Limited Position choice is for stepper amplifiers only). 
5.6.7.6  Click OK to save changes to volatile memory and close the 
Custom Output Configuration screen. 
5.6.8: Save Input/Output Changes 
5.6.8.1  On the Input/Output screen, click Close.
5.6.8.2  On the Main screen, click Save to Flash.