User guide
Parameter Dictionary  Parameters 
2.1: Parameters Sorted by ASCII Interface Parameter ID 
ASCII 
DvcNet 
MACRO 
CAN/ECAT 
IDX:SUB 
Bank 
Type 
Description 
0x00 
0x01 
0x400 
0x2380:1 
RF 
U16 
Current Loop Proportional Gain (Cp). 
0x01 
0x02 
0x401 
0x2380:2 
RF 
U16 
Current Loop Integral Gain (Ci). 
0x02 
0x03 
0x402 
0x2340 
RF 
INT16 
Current loop programmed value. This current will be used to command the drive 
when Desired State (0x24) is set to 1. Units: 0.01 A. 
0x03 
0x04 
0x403 
0x2203 
R* 
INT16 
Winding A Current. Actual current measured at winding A. Units: 0.01 A. 
0x04 
0x05 
0x404 
0x2204 
R* 
INT16 
Winding B Current. Actual current measured at winding B. Units: 0.01 A. 
0x05 
0x06 
0x405 
0x2210 
R* 
INT16 
Current Offset A. Offset value applied to the winding A current reading. This offset is 
calculated by the drive at startup. Units: 0.01 A. 
0x06 
0x07 
0x406 
0x2211 
R* 
INT16 
Current Offset B. Offset value applied to the winding B current reading. This offset is 
calculated by the drive at startup. Units: 0.01 A.  
0x07 
0x08 
0x407 
0x2212 
R* 
INT16 
X axis of calculated stator current vector. Units: 0.01 A. 
0x08 
0x09 
0x408 
0x2213 
R* 
INT16 
Y axis of calculated stator current vector. Units: 0.01 A. 
0x09 
0x0A 
0x409 
0x221A 
R* 
INT16 
Current loop output, X axis of stator space. 
0x0A 
0x0B 
0x40A 
0x221B 
R* 
INT16 
Current loop output, Y axis of stator space. 
0x0B 
0x0C 
0x40B 
0x2214 
R* 
INT16 
Actual Current, D axis of rotor space. Units: 0.01 A. 
0x0C  0x0D  0x40C  0x2215  R*  INT16  Actual Current, Q axis of rotor space. Units: 0.01 A. 
0x0D 
0x0E 
0x40D 
0x2216 
R* 
INT16 
Commanded current, D axis of rotor space. Part of the internal current loop 
calculation. Units: 0.01 A. 
0x0E 
0x0F 
0x40E 
0x2217 
R* 
INT16 
Commanded Current, Q axis of rotor space. Part of the internal current loop 
calculation. Units: 0.01 A. 
0x0F 
0x10 
0x40F 
 None 
R* 
INT16 
Current Error, D axis of rotor space. Units: 0.01 A. 
0x10 
0x11 
0x410 
 None 
R* 
INT16 
Current Error, Q axis of rotor space. Units: 0.01 A. 
0x11 
0x12 
0x411 
 None 
R* 
INT16 
Current Integral Value, D axis of rotor space. 
0x12  0x13  0x412   None  R*  INT16  Current Integral Value, Q axis of rotor space. 
0x13 
0x14 
0x413 
0x2218 
R* 
INT16 
Current Loop Output, D axis of rotor space. 
0x14 
0x15 
0x414 
0x2219 
R* 
INT16 
Current Loop Output, Q axis of rotor space. 
Copley Controls  Page 12   