User guide
Parameter Dictionary  Parameters 
ASCII 
DvcNet 
MACRO 
CAN/ECAT 
IDX:SUB 
Bank 
Type 
Description 
Velocity  0.1 counts/s. 
Position  
Counts. 
0x9B 
0x9C 
0x49B 
0x2333 
RF 
U16 
Function Generator Duty Cycle (square wave only). 
Units: 0.1% (for instance, 1000 for 100%). 
0x9C 
0x9D 
0x49C 
0x2384:8 
F* 
U16 
Hysteresis For Maximum Bus Voltage Cut-Out. Units: 0.1 V. 
0x9D 
0x9E 
0x49D 
0x2384:18 
F* 
U16 
PWM Dead Time At Continuous Current Limit. This parameter gives the PWM dead 
time used at or above the continuous current limit. The dead time below the 
continuous current limit is a linear function of this parameter and PWM Dead Time At 
Zero Current (0x9F).  Units: CPU cycles. 
0x9E 
0x9F 
0x49E 
0x2384:17 
F* 
U16 
Drive Minimum PWM Off Time. This parameter gives the minimum amount of time 
for which all PWM outputs must be disabled for each current loop cycle. Units: 10 ns. 
0x9F 
0xA0 
0x49F 
0x2384:19 
F* 
U16 
PWM Dead Time At Zero Current. This parameter gives the PWM dead time at zero 
current. The dead time above zero current is defined by a linear function of this 
parameter and PWM Dead Time At Continuous Current Limit (0x9D). Units: CPU 
cycles. 
0xA0 
0xA1 
0x4A0 
0x1002 
R* 
U32 
Drive Event Status Register. Bit-mapped as follows: 
Bits 
Description 
0 
Short circuit detected.  
1 
Drive over temperature. 
2  Over voltage. 
3 
Under voltage. 
4 
Motor temperature sensor active. 
5 
Encoder feedback error. 
6 
Motor phasing error. 
7 
Current output limited. 
8 
Voltage output limited. 
9  Positive limit switch active. 
10 
Negative limit switch active. 
11 
Enable input not active. 
12 
Drive is disabled by software. 
13 
Trying to stop motor. 
Copley Controls  Page 31   