User guide
Parameter Dictionary  Parameters 
ASCII 
DvcNet 
MACRO 
CAN/ECAT 
IDX:SUB 
Bank 
Type 
Description 
5  If set, exit table in forward direction. 
6 
If set, use the Camming Internal Generator. The internal generator runs at the constant 
velocity programmed in Camming Master Velocity (0x109). 
If clear, use digital command input as configured in using Copley’s CME 2 software camming 
controls or Input Pin States (0xA6). 
7  If set, run tables stored in RAM. If clear, use tables stored in the flash file system. 
8-11 
Input number to use as Cam Trigger. Note: a value of 0 selects IN1, 1 selects IN2, etc. 
12-14 
Cam Trigger type: 
Value 
Type 
0 
None (Continuous): The active Cam Table is repeated continuously. 
1 
Use Input, Edge: The active Cam Table begins executing on the rising edge of the 
input pin selected by bits 8-11. 
2 
Use Input, Level: The active Cam Table will run as long as the input selected by bits 
8-11 is high. 
3  Use Master (Secondary) Encoder Index: The active Cam Table is executed when 
the drive receives an index pulse from the Master encoder. Index pulses received 
during execution are ignored. 
7 
Never trigger. This can be used to stop a CAM currently in progress 
0x106 
0x107 
0x506 
0x2361 
RF 
INT16 
Camming delay, forward motion. This gives the delay (in master encoder counts) 
used when entering a cam table in the forward direction. Units: master command 
counts.  
0x107 
0x108 
0x507 
0x2362 
RF 
INT16 
Camming delay, reverse motion. This gives the delay (in master encoder counts) 
used when entering a cam table in the reverse direction. Units: master command 
counts. 
0x108 
0x109 
0x508 
None  
R 
INT16 
Writing any value to this parameter will cause any CANopen PDO objects configured 
with type code 254 to be sent. This parameter is primarily useful for triggering a PDO 
from within a CVM program. 
Reading this parameter does not return any useful information. 
0x109 
0x10A 
0x509 
0x2363 
RF 
INT 32 
Camming Master Velocity. Constant velocity of the Camming Internal Generator.  
Units: 0.1 counts/s. 
0x10A 
0x10B 
0x50A 
0x2403 
R* 
INT 32 
Captured Home Position. Provides the position that the axis was in when an input pin 
configured as a home switch input became active. Configured by setting bits in the 
Position Capture Control Register (0x6C). Status of the captured data can be 
checked in the Position Capture Status Register (0x6D). Reading this variable resets 
Copley Controls  Page 53   