User guide
Xenus Plus User Guide    Wiring 
Copley Controls  103 
4.10: Secondary I/O 
4.10.1: XEL/XPL/XML (J9) 
Mating Connector 
Description 
Manufacturer PN 
Wire Size 
15 Position, High-density, D-Sub, male, solder cup. 
Norcomp: 180-015-
103L001 
24 - 30 AWG 
Backshell 
Norcomp: 979-009-
020R121 
Solder style connector included in Connector Kits XEL-CK, XML-CK, and XPL-CK. 
Pin connections for the bulkhead connector on the drive are shown here: 
J9 Pin Description 
Pin 
Signal 
Function 
1 
Frame Ground 
Cable shield connection. 
2 
COMM_A 
Common signal for first group of optically isolated programmable inputs. 
3 
IN7 GPI 
Optically isolated programmable input. 
4 
IN8 GPI 
5 
IN9 GPI 
6 
IN10 GPI 
7 
COMM_B 
Common signal for second group of optically isolated programmable inputs. 
8 
IN11 GPI 
Optically isolated programmable input. 
9 
IN12 GPI 
10 
IN13 GPI 
11 
IN14 GPI 
12 
OUT5+ GPI 
Optically isolated programmable output positive signal. 
13 
OUT5- GPI 
Optically isolated programmable output negative signal. 
14 
OUT4+ GPI 
Optically isolated programmable output positive signal. 
15 
OUT4- GPI 
Optically isolated programmable output negative signal. 
1
5
11
15
10
6