User guide
Xenus Plus User Guide    Wiring 
Copley Controls  108 
Axis B 
These inputs are for Axis B and are dedicated to specific functions, depending on operating mode. 
Mode 
Selected Command Source 
Function 
Digital Input 
Single Ended 
Digital Input 
Differential 
Multi-Mode 
Port 
Current & Velocity 
PWM 50% 
IN 14 
IN12(+) & IN13(-) 
A & /A 
PWM Input 
Current & Velocity 
PWM 100% 
IN 14 
IN12(+) & IN13(-) 
A & /A 
PWM Input 
IN 15 
IN14(+) & IN15(-) 
B & /B 
Direction Input 
Position 
Pulse & Direction 
IN 14 
IN12(+) & IN13(-) 
A & /A 
Pulse Input 
IN 15 
IN14(+) & IN15(-) 
B & /B 
Direction Input 
Position 
Up/Down 
IN 14 
IN12(+) & IN13(-) 
A & /A 
Count Up 
IN 15 
IN14(+) & IN15(-) 
B & /B 
Count Down 
Position 
Quadrature 
IN 14 
IN12(+) & IN13(-) 
A & /A 
Channel A 
IN 15 
IN14(+) & IN15(-) 
B & /B 
Channel B 
Digital Inputs (IN1~IN5, IN11~IN15) Wiring Diagram 