User guide
Xenus Plus User Guide    Wiring 
Copley Controls  110 
4.10.3: Isolated Control XE2/XP2/800-1808 (J9) 
J9 is a 26 position male D-sub connector used for isolated controls 
Mating Connections 
Description 
Manufacturer PN 
Wire Size 
26 Position, High-Density D-Sub Female Solder 
Style Connector 
Norcomp 180-026-
203L001 
24 - 30 AWG 
Back shell 
Norcomp 979-015-
020R121 
Solder style connector included in Connector Kits XE2-CK and XP2-CK. 
Pin connections for the bulkhead connector on the drive are shown here: 
XE2/XP2/800-1808 Pin Description 
Pin 
Signal 
Function 
1 
Frame Ground 
Cable shield connection. 
2 
IN6 GPI 
Optically isolated programmable input. 
3 
IN7 GPI 
4 
IN8 GPI 
5 
IN9 GPI 
6 
COM1 
Common signal for first group of optically isolated programmable inputs (IN6-IN9) 
7 
IN16 GPI 
Optically isolated programmable input. 
8 
IN17 GPI 
9 
IN18 GPI 
10 
OUT1- GPI 
Optically isolated programmable output negative signal. 
11 
OUT2- GPI 
12 
OUT3- GPI 
13 
OUT4- GPI 
14 
OUT5- GPI 
15 
N/C 
No connection. 
16 
N/C 
No connection. 
17 
COM2 
Common signal for first group of optically isolated programmable inputs (IN16-IN19) 
18 
IN19 GPI 
Optically isolated programmable input. 
19 
OUT1+ GPI 
Optically isolated programmable output positive signal. 
20 
OUT2+ GPI 
Optically isolated programmable output positive signal. 
Continued… 
9
1
18
26
19
10