User guide
Xenus Plus User Guide    Ordering Guide and Accessories 
Copley Controls  156 
F.7: Copley Standard Regen Resistor Specifications 
F.7.1: Specifications 
Specifications for Copley’s standard regen resistors are described below. 
Model 
Resistance 
Default 
Continuous 
Power 
Max 
Continuous 
Power 
Peak 
Power 
Peak 
Power 
Time 
For Use With 
XTL-RA-03 
30 Ohms 
65 W 
400 W 
5 kW 
1000 ms 
XEL/XML/XPL-230-18 
XEL/XML/XPL-230-18-R 
XTL-RA-04 
15 Ohms 
65 W 
400 W 
10 kW 
1000 ms 
XEL/XML/XPL-230-36 
XEL/XML/XPL-230-36-R 
XEL/XML/XPL-230-40 
XEL/XML/XPL-230-40-R 
XE2/XP2-230-20/800-
1782/800-1808 
XE2/XP2-230-20-R 
WARNING 
High Temperature Risk. 
Setting Default Continuous Power for a standard Copley regen resistor to a value greater 
than the default of 65 W may cause the resistor casing to heat to temperatures that could 
cause injury. If higher settings are required, contact Copley Controls customer support. 
Failure to heed this warning can cause equipment damage or injury. 
F.7.2: Dimensions 
The diagram below shows XTL-RA-03 and XTL-RA-04 mounting dimensions (in mm). 
!