User guide
Xenus Plus User Guide    Operational Theory 
Copley Controls  36 
2.10: Status Indicators 
2.10.1: XEL J6 STAT & NET: Drive and EtherCAT State Machine Indicators 
XEL J6 STAT Indicator: Drive Status 
XEL Drive status indicator color/blink codes are described below. 
Color/Blink Code 
Meaning 
Not illuminated 
No +24 Vdc power to drive. 
Steady green 
Drive is enabled and operational. 
Slow-blinking green 
Drive is disabled. No faults or warnings are active. 
Fast-blinking green 
A limit switch is active. The drive is enabled. 
Green flash twice 
followed by a pause 
STO is active, One or both STO inputs are de-energized. The drive is hardware & software 
enabled but the PWM outputs cannot produce current in the motor when STO is active. 
Steady red 
A non-latched fault has occurred. 
Blinking red 
A latched fault has occurred. 
XEL J6 NET Indicator: EtherCAT State Machine 
Run (Green) 
Color/Blink Code 
Meaning 
Not illuminated 
Initialization 
Blinking 
Pre-operational. 
Single flash 
Safe-operational. 
Steady 
Operational. 
Error (Red) 
Not illuminated 
No error. 
Blinking 
Invalid configuration. A change of state commanded by the master is not possible or is illegal. 
Single flash 
Local error. The slave has initiated a change of state by itself in response to an error. 
Double flash 
Watchdog timeout. The EtherCAT sync manager watchdog timer has timed out. 
STAT-Drive Status
NET-EtherCAT Network Status
J6
J7
Out (B)
In (A)
Activity Status (Yellow)
Activity Status (Yellow)
Link Status (Green)
Link Status (Green)