User guide
Xenus Plus User Guide    Specifications 
Copley Controls  60 
3.3: Power Output 
Model 
XEL-230-18 (-R) 
XPL-230-18 (-R) 
XML-230-18 (-R) 
XEL-230-36 (-R) 
XPL-230-36 (-R) 
XML-230-36 (-R) 
XEL-230-40 (-R) 
XPL-230-40 (-R) 
XML-230-40 (-R) 
XE2-230-20 (-R) 
XP2-230-20 (-R) 
800-1808 
800-1782 
Peak Current 
18 Adc 
 [12.7 Arms] 
36 Adc 
[25.5 Arms] 
40 Adc 
[28.3 Arms] 
20 Adc 
[14 Arms] 
Peak Current Time 
1 Second 
Continuous Current* 
6 Adc 
[4.24 Arms] 
12 Adc 
[8.5 Arms] 
20 Adc 
[14.1 Arms] 
10 
[7 Arms] 
Efficiency 
>97% @ 230 Vac and rated continuous current 
Output Type 
3-phase IGBT inverter 
16 kHz center-weighted PWM 
space-vector modulation 
PWM Ripple Frequency 
32 kHz 
Minimum Load 
Inductance 
400 uH line-to-line** 
NOTE: See Xenus Plus Filter (p. 139). 
* Heat sinking and/or forced air cooling required for continuous output power rating 
** Consult factory for operation with inductance lower than 400 uH 