User guide
Xenus Plus User Guide    Specifications 
Copley Controls  72 
3.18: Network Interfaces 
Model 
XEL/XE2/800-1782 
XPL/XP2 
XML/800-1808 
Channels 
1 
Connectors 
2 eight-position (RJ-45 style). 
2 Duplex type SC optical 
fiber connector. 
Signals 
100BASE-TX 
CAN_H, CAN_L, 
CAN_Gnd (CAN +5 Vdc 
Pass though only) 
MACRO (Motion And 
Control Ring Optical). 
Format 
EtherCAT 
CAN V2.0b physical layer 
for high-speed connections 
compliant 
Protocol 
CANopen over EtherCAT 
(CoE) based on DSP-402 
for motion control devices. 
Motion Control Device 
Under DSP-402 of the 
CANopen DS-301 V4.01 
(EN 50325-4) Application 
Layer 
MACRO 
Supported Modes 
Cyclic Synchronous 
Position & Velocity. 
Profile Current, Velocity, 
and Position, PVT 
(Position-Velocity-Time), 
and Homing. 
Torque (current), Velocity. 
Node Address Selection 
Slaves are automatically 
assigned addresses based 
on their position in the bus. 
Two 16-position 
hexadecimal rotary 
switches can be used to 
define a cabling-
independent Station Alias. 
Two 16-position 
hexadecimal rotary 
switches on front panel 
OR programmable digital 
inputs 
OR stored in flash memory 
OR combination of above. 
Two 16-position 
hexadecimal rotary 
switches are used to define 
a MACRO node address. 
Bus Termination 
No termination required. 
External 121   resistor 
across CAN_H and CAN_L 
when termination plug is 
installed in second 
connector. 
No termination required. 
Function 
Real-time motion control 