User guide
Xenus Plus User Guide    Wiring 
Copley Controls  90 
4.5.2: XE2/XP2/800-1782/800-1808 (J5) 
The following information is for XE2/XP2/800-1782/800-1808 drives only. 
Mating Connector 
Description 
Euro-style 5.0 mm pluggable female terminal block. 
Manufacturer PN 
Wago: 721-105/026-047 (Note 1) 
Wire Size 
28 - 14 AWG 
Recommended Wire 
18 AWG 
Wire Insertion/Extraction Tool 
Wago: 231-131 
Standard connector and tool are included in Connector Kits XEL-CK, XML-CK, and XPL-CK. 
Note 1: For RoHS compliance, append “/RN01-0000” to the part numbers listed above. 
Pin Description 
Pin 
Signal 
Function 
1 
RTN 
+24 Vdc return from battery. 
2 
Brake B 
Return or low side of motor brake B. 
3 
Brake A 
Return or low side of motor brake A. 
4 
Brake+24 Vdc 
+24 Vdc for both brakes. 
5 
24 Vdc input 
+24 Vdc Logic power supply from battery. 
Logic Supply / Brake Wiring Diagram 
Note that the +24Vdc supply must be a SELV or PELV type in applications using the XE2/XP2/800-1808 
STO feature. See the Xenus Plus Dual-Axis STO Manual for further details.   
Drive J5
Isolated Logic
Pow er Supply
for Brake A
J5-5
J5-4
+24 V
BRK-A
RTN
Brake A
J5-3
J5-2
J5-1
BRK +24 Vdc
BRK-B
Isolated Logic
Pow er Supply
for Brake B
Brake B
+24 Vdc
Power
Supply
(Required)