User guide
Xenus Plus User Guide    Wiring 
Copley Controls  93 
4.6.2: XE2/XP2/800-1782/800-1808 (J6) 
The following information is for XE2, XP2, 800-1782, and 800-1808 drives only. 
Mating Connector 
Description 
Manufacturer PN 
Wire Size 
Connector, D-Sub, 9-position, standard 
AMP/Tyco: 205204-4 
AMPLIMITE HDP-20 Crimp-Snap contacts, 24-20AWG, sel 
AU/NI 
AMP/Tyco: 66506-9  
24-20AWG 
Backshell, D-Sub, RoHS, metallized, for J6 
Norcomp: 979-009-020R121 
Solder style connector included in Connector Kits XE2-CK and XP2-CK. 
Pin Description 
Pin 
Signal 
Function 
1 
Frame Ground 
Cable shield connection. 
2 
STO-1(+) 
STO-1 Input 
3 
STO-1(-) 
4 
STO-2(+) 
STO-2 Input 
5 
STO-2(LO-) 
6 
STO-1(+) 
STO-1 Input. Pins 2 & 6 and pins 3 & 7 are connected 
together inside the drive. This second set of connection 
points is provided to simplify wiring of the STO bypass 
connections. 
7 
STO-1(-) 
8 
STO-GND 
24V ground 
9 
STO-24V 
Internal power source for STO bypassing 
 DANGER 
Refer to the Xenus Plus Dual-Axis STO User Manual 
The information provided in the Xenus Plus Dual-Axis STO User Manual must be 
considered for any application using the XE2/XP2/800-1808 drive STO feature. 
Failure to heed this warning can cause equipment damage, injury, or death. 
. 
!