User guide
Homing  CME 2 User Guide 
146  Copley Controls 
…Homing Parameters, continued: 
Slow Velocity 
The velocity used to find a switch edge, incremental or analog encoder 
index pulse, or hard stop. 
Accel/Decel 
The acceleration and deceleration rate used during homing. 
Offset 
Execute a move of this distance after the reference is found. Set actual 
position to 0 and call the new position home. 
Current Limit 
Hard stop home is reached when the amplifier outputs the homing Current 
Limit continuously for the time specified in the Delay Time. 
Current Delay Time 
Following Warning 
Shows the programmed following warning level. 
Actual Current 
Shows actual current being applied to windings during homing. 
Actual Position 
Shows the actual position of the axis. 
Homing Adjustment 
Shows the Home offset measured after homing is performed. 
Test without home 
adjustments 
Selecting this option and pressing the Home Button tests the adjusted 
home position without making any changes to the saved home position. 
The resulting homing offset is reported in the Homing Adjustment text field. 
3 
Optionally click Home to begin a homing sequence. To stop immediately, click Stop. 
4 
Click Save to save the settings to flash memory. Click Exit to close the screen.  
.  