User guide
Control Panel    CME 2 User Guide 
150  Copley Controls 
14.4: Control Functions 
The Control area of the screen provides functions related to overall amplifier control. The 
screen options vary with model and configuration. 
Use the Control Panel Control Functions 
Control the operational state of the amplifier using the buttons as described 
below. 
Control 
Description 
Enable 
Click to software enable the amplifier. 
Disable 
Click to software disable the amplifier. This will also stop any CVM 
programs that are running. 
Set Zero Position 
Click to set the amplifier’s actual position counter to zero. 
Clear Faults 
Click to clear all amplifier faults. 
Reset 
Click to reset the amplifier. 
!
WARNING 
Risk of unexpected or uncontrolled motion. 
Using the CME 2 Set Zero Position function while the amplifier is operating under 
external control could cause unexpected or uncontrolled motion.  
Failure to heed this warning can cause equipment damage. 