User guide
Scope Tool    CME 2 User Guide 
156  Copley Controls 
15.3: Trace Channel Variable Parameters 
Choose a trace variable for display in a Scope channel 
1 
 Click the channel button. 
2 
Choose a category and a trace variable. 
Category 
Trace Variable 
Category 
Trace Variable 
Disabled 
<Channel disabled, no 
associated variable> 
Misc. 
Motor Phase Angle, Amplifier 
Temperature, Hall States 
Current 
Commanded Current, 
Actual Current, Limited 
Current., 
I
2
T Amplifier Accumulator,  
I
2
T Motor Accumulator. 
Digital Inputs 
Digital input line states 
Velocity 
Profile Velocity, 
Commanded Velocity, 
Limited Velocity, Actual 
Motor Velocity, Actual Load 
Velocity, Unfiltered Motor 
Velocity, Velocity Error 
Digital 
Outputs 
Digital output line states 
Position 
Commanded Position, 
Limited Position, Actual 
Load Position, Actual Motor 
Position, Following Error, 
Passive Load Position 
Event Status 
Faults 
See Fault 
Configuration 
Parameters 
(p. 88). 
Short Circuit, Amp Over 
Temperature, Over Voltage, Under 
Voltage, Motor Over Temperature, 
Feedback Error, Motor Phasing 
Error, Following Error, Command 
Input Fault, Amplifier Fault (a 
latched fault is active).  
Acceleration 
Profile Acceleration 
Event Status 
Warnings 
See Custom 
Event 
Functions 
(p. 62). 
Current Limited, Voltage Limited, 
Positive Limit Switch, Negative Limit 
Switch, Following Warning, Velocity 
Limited, Acceleration Limited, 
Positive Software Limit, Negative 
Software Limit, Pos Outside of 
Tracking Window, Vel Outside of 
Tracking Window.  
Voltage 
Analog Command 
Bus Voltage 
Analog sin Input 
Analog cos Input 
Terminal Voltage Stepper 
Terminal Voltage Servo 
Event Status 
Misc. 
See Custom 
Event 
Functions 
(p. 62). 
Amp Disabled by Hardware, 
Amp Disabled by Software, 
Attempting to Stop Motor, Motor 
Brake Active, PWM Outputs 
Disabled, Position Has Wrapped, 
Home Switch Active, In Motion, 
Phase Not Initialized.  
3 
Click OK. 