User guide
CME 2 User Guide    Homing Methods 
Copley Controls  199 
E.3: Homing Method Descriptions 
E.3.1: Set current position as home 
The current position is the home position.  
E.3.2: Next Index 
Direction of Motion: Positive 
Home is the first index pulse found in the positive direction. Direction of motion is positive. 
If a positive limit switch is activated before the index pulse, an error is generated.  
Index Pulse
H
Direction of Motion: Negative 
Home is the first index pulse found in negative direction. Direction of motion is negative. If 
a negative limit switch is activated before the index pulse, an error is generated. 
Index Pulse
H