User guide
Gain Scheduling   CME 2 User Guide 
224  Copley Controls 
… Create a Gain Scheduling Table, continued: 
4 
If there is already a table stored in flash: 
Optionally Save Settings and Table Data to Disk (p. 226).  
Then click the Delete tool to delete the gain scheduling table data from 
amplifier flash and PC RAM. 
5 
On the Table tab, click the Create a new gain scheduling table tool. See the 
prompt: 
6 
Enter the number of lines (the number of gain adjustment specifications). 
Click OK. 
7 
Enter the Key Parameter and gain adjustment values. All values must be integer, and 
each Key Parameter value must be greater than the previous as described in Gain 
Scheduling Table Guidelines (p. 227). Click in a field to enter or modify a value. 
Standard mouse and keyboard editing techniques are available. 
8 
On the Table tab, click Save gain scheduling table and setup to amplifier 
flash memory before attempting to run the new table. This saves the Table tab 
data and all Config tab settings. 
9 