User guide
CME 2 User Guide    Amplifier Setup Procedure 
Copley Controls  29 
3.2: Setup Procedure 
1 
Prepare for setup 
 
Understand this procedure’s Warnings and Notes (p. 28). 
 
Verify that amplifier power is OFF. 
 
Verify wiring and connections. 
 
Make sure motor is securely fastened with no load connected. 
 
Apply power to the amplifier. 
 For off-line amplifiers apply 24V only. 
 For DC amplifiers apply AUX HV only. 
2 
Start CME 2 and enter Basic Setup parameters 
 
 Double-click CME 2 icon on the Windows desktop to start CME 2. 
 
If necessary, Connect to an Amplifier in CME 2 (p. 20) from the list in the Copley 
Neighborhood tree. 
 
 If the Basic Setup screen does not appear, click the Basic Setup button. 
 
Choose: 
In most cases, click Change Settings to Change Basic Setup 
Settings (p. 34). 
Then proceed to Step 3 of this Setup Procedure, 
Enter Motor/Feedback/Brake Stop parameters (p. 30). 
OR 
To load a .ccx file that was prepared for the amplifier/motor 
combination, see Copy Amplifier Data (p. 177). Then proceed to 
Step 13 of this Setup Procedure, Test with load attached (p. 32). 
OR 
To complete the setup for a ServoTube motor, click ServoTube 
Setup and see ServoTube Setup (p. 39). 
Continued… 