User guide
Basic Setup    CME 2 User Guide 
36  Copley Controls 
4.3: Feedback Options 
View or change the settings described below. Options vary with amplifier model. 
Setting 
Description 
Hall Type 
Select Hall type: None, Digital, or Analog (Analog is used with Copley 
Controls ServoTube motors). 
Hall Phase Correction 
If selected, will enable error checking between Hall switches and 
encoder based phase angle. See Faults (p. 87). 
Motor Encoder 
Select type and source of motor feedback. 
  None: No motor encoder. 
  Primary Incremental: Incremental encoder on primary feedback 
connector. 
  Secondary Incremental: Incremental encoder on multi-mode port. 
  Panasonic Incremental A Format 
  SSI 
  EnDat 
  BiSS 
  Absolute A 
  Tamagawa Absolute A 
  Panasonic Absolute A Format 
  Analog: Analog encoder on primary feedback connector. 
  Low Frequency Analog: Copley ServoTube motor on primary 
feedback connector. 
  Resolver: Resolver (–R) version of a Copley Controls amplifier on 
primary feedback connector. 
Additional encoder types are supported by certain Copley Controls 
amplifier models. See the amplifier data sheet for more information. 
Position Encoder 
Select type and source of Position (load) feedback. 
  None: No position encoder 
  Primary Incremental: Incremental encoder on primary feedback 
connector. 
  Secondary Incremental: Incremental encoder on multi-mode Port.  
  Analog: Analog encoder on primary feedback connector. 
Position Encoder 
Type 
Select the type of Position (load) encoder: 
  Rotary 
  Linear 
Use Position Encoder 
in Passive (Monitor) 
Mode 
When this is checked, the position of the position encoder will be 
reported by the passive load position variable but it will not be used to 
control the position of the axis. 
Continued… 