User guide
Motor/Feedback    CME 2 User Guide 
48  Copley Controls 
Absolute A 
In the Bits text field specify the number of bits used for single turn resolution (see encoder 
data sheet). In the Number of Revolutions text field specify the number of turns (see 
encoder data sheet). Optionally, enter a number of counts per rev bits to ingnore in the 
specified box. Choose bit rate. 
!
WARNING 
When a battery error exists, absolute position may not be true (whether 
the Ignore Battery Error option has been checked or not). 
FAILURE TO HEED THIS WARNING CAN CAUSE EQUIPMENT 
DAMAGE, INJURY, OR DEATH. 
Tamagawa 
Absolute A 
and 
Panasonic 
Absolute A 
Format 
In the Bits text field specify the number of bits used for single turn resolution (see encoder 
data sheet). In the Number of Revolutions text field specify the number of turns (see 
encoder data sheet). Optionally, enter a number of counts per rev bits to ignore in the 
specified box. The bit rate defaults to 2.5 MB/s. Zero encoder in the specified box when 
needed. 