Any of the amplifier’s digital outputs can be programmed to respond to a combination of 
events including faults, warnings, and status indications. The output goes active when one 
or more of the selected events take place. 
Configure a Custom Event output 
1 
Choose Custom Event for an output and then click Configure Custom to open the 
Event Configuration screen. 
2 
Select one or more Custom Event Functions (p. 62).  
Multiple functions are OR’ed together, so any event activates the output. 
3 
Choose Output Active Hi/Off or Output Active Lo/On. 
4 
To latch the output, set the Latch Output option. 
The Clear button clears all check marks. 
!
DANGER 
Latching an output does not eliminate the risk of unexpected motion with 
non-latched faults. 
Associating a fault with a latched, custom-configured output does not latch the 
fault itself. After the cause of a non-latched fault is corrected, the amplifier re-
enables without operator intervention. In this case, motion may re-start 
unexpectedly. 
Failure to heed this warning can cause equipment damage, injury, or death. 