User guide
Digital Inputs and Outputs    CME 2 User Guide 
64  Copley Controls 
6.2.4: Custom Digital Output Settings: Custom Trajectory Status 
Any of the amplifier’s digital outputs can be programmed to respond to a combination of 
amplifier trajectory status conditions. The output goes active when one or more of the 
conditions is met. 
Configure a Custom Trajectory Status output 
1 
Choose Custom Trajectory Status for an output and then click Configure Custom to 
open the Trajectory Status Configuration screen. 
2 
Select one or more trajectory status conditions described below. 
Multiple functions are OR’ed together, so any status match activates the output. 
Trajectory Status Functions 
Status 
Description 
Homing Error 
Activate output if an error occurred in the last homing attempt. 
Referenced 
(Homed) 
Activate output if the most recent homing attempt was successful. 
Homing in 
Progress 
Activate output when a homing move is in progress. 
Move Aborted 
Activate output if move is aborted. 
Trajectory 
Generator 
Running 
Activate output while trajectory generator is generating a move. 
Camming 
Buffer Error 
A camming buffer error has occurred.  
3 
Choose Output Active High to have the output go high when active or Output Active 
Low to have the output go low when active. 
4 
Click OK to save changes to amplifier RAM and close the screen. 










