User guide
CME 2 User Guide    Command Inputs 
Copley Controls  73 
7.2: PWM Input Settings 
View or change the settings described below. 
Parameter 
Description 
Scaling 
Current mode: output current at 100% duty cycle. 
Range: 0 to 10,000,000 A. Default: Peak Current value. 
Velocity mode: output velocity at 100% duty cycle. 
Range: 0 to 100,000 rpm (mm/sec).  
Default: Maximum Velocity value. 
PWM Input Type 
One wire 50% or two wire 100% with direction. 
Options 
Invert PWM input: Inverts the PWM logic. 
Allow 100% output: Overrides the 100% command safety measure.  
See Failsafe Protection from 0 or 100% Duty Cycle Commands (p. 75). 
Invert Sign Input: In 100% duty cycle mode, inverts the polarity of the directional 
input. 
For more information, see PWM Input Notes (p 74). 










