9:  FAULTS 
This chapter shows how to configure the amplifier’s fault latching. Perform the basic steps 
outlined below. Details follow in the chapter: 
1 
 Click Configure Faults to open Faults Configuration screen. 
2 
Select the faults to latch. See Fault Configuration Parameters (p. 88). 
3 
Click OK to close screen and save changes to amplifier RAM. 
4 
 On the Main screen, click Save to Flash to avoid losing the changes. 
!
DANGER 
Risk of unexpected motion with non-latched faults. 
After the cause of a non-latched fault is corrected, the amplifier re-enables 
the PWM output stage without operator intervention. In this case, motion 
may re-start unexpectedly. Configure faults as latched unless a specific 
situation calls for non-latched behavior. When using non-latched faults, be 
sure to safeguard against unexpected motion. 
Failure to heed this warning can cause equipment damage, injury, or 
death. 