9.3.6: Tracking Window Details 
Proper Tracking Over Time 
As described earlier, position error is the difference between the limited position output of 
the trajectory generator and the actual position. Velocity error is the difference between 
commanded and actual velocity. 
When the position or velocity error exceeds the programmed tracking window value, a 
status word bit is set. The bit is not reset until the error remains within the tracking window 
for the programmed tracking time.  
Velocity Tracking Illustration 
The following diagram illustrates the use of tracking window and time settings in velocity 
mode. 
± Tracking Window
Tracking
Time
Limited Velocity
Actual Velocity
Tracking Window
Output