Instruction manual

7-10
Setting Procedure of Horizontal Timing
7.3.4 Horizontal Timing (Fine Adjustment)
The H-PHASE (FINE) is used to set the horizontal timing.
Settable Range
±100, in 1 steps
The one step (i.e., ±0.0741 μs) is divided into about ±100.
Setting Procedure of Horizontal Timing
Display the H-PHASE (COARSE) by using the [
5
] and [
6
]
keys.
Press the ENTER key.
Press the ENTER key.
1.GL SETTING
t
GENLOCK TIMIN
2.GENLOCK TIMING
v
H-PHASE (COARSE)
3.H(COARSE)R:2.997H
GL. +0.0741 μ
Display the GENLOCK TIMING by using the [
5
] and [
6
]
keys.
2.GENLOCK TIMING
v
H-PHASE (COARSE)
Press the ENTER key. Press the MENU key to cancel.
Sets the timing by using the [
5
] and [
6
] keys.
The internal reference signal is displayed at the upper-right
corner of the screen.
Display the H-PHASE (FINE) by using the [
5
] and [
6
] keys.
Press the ENTER key
Press the ENTER key.
1.GL SETTING
t
GENLOCK TIMIN
2.GENLOCK TIMING
t
H-PHASE (FINE
3.H(FINE) R:2.997H
Display the GENLOCK TIMING by using the [
5
] and [
6
] keys.
2.GENLOCK TIMING
t
H-PHASE (FINE
Press the ENTER key. Press the MENU key to cancel.
Sets the timing by using the [
5
] and [
6
] keys.
The internal reference signal is displayed at the upper-right corne
r