Service manual

Publication Number: 620058442 - 13 - © 2013-2015, Cornelius Inc
Quest Elite QLT 2000
PLANNED MAINTENANCE
Daily – Flushing the system
1. Set both flush switches to “Flush” position.
2. Open the cabinet door. Move both LH and RH flush switches from the
“Run” position to the “Flush” position. Close the cabinet door.
Figure 27.
3. Place small cold-drink cup under each dispensing nozzle.
4. Place a small, empty, cold-drink cup on the drip tray under the nozzles.
Figure 28.
5. Flush nozzles.
6. Push the Cancel/Pour dispenser switches and hold down for 2 or 3 sec-
onds, until clear water is dispensed from both nozzles
Figure 29.
7. Reset the flush switches to “Run” position.
8. Open the cabinet door. Move the flush switches from the “Flush” position to
the “Run” position. Close the cabinet door.
Figure 30.
9. Clean nozzles and mixers.
10. Turn the nozzle to the left or right ¼ turn and pull down to remove the noz-
zle and static mixer. Take the nozzles and static mixers to the three-com-
partment-sink. Rinse both with hot tap water to remove any pulp.
Figure 31.
11. Replace nozzles and mixers.
12. Reinstall the nozzles and static mixers on the dispenser.
Figure 32.